A large cylindrical reservoir needs to be filed with water after it was drained for maintenance. The West City fire department is asking what time the reservoir will be filled. RESERVOIR PUMP The 7.0m diameter tank is filled by pumping water into the tank. The water fills the tank through a 55.0m long. 0.07m diameter pipe connected to the wall at the base of the tank, The pipe has a Darcy-Weisbach friction factor of 0.04. The fire department has specihed that the tank needs to be filled to 2.0m. The pump maintains a constant discharge pressure of 30kPa You write the following email, inputting each value to 1 decimal place (without units, and rounding the time the tank will iled the nearest 30 minutes.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Concept explainers
Question

4

A large cylindrical reservoir needs to be filled with water after it was drained for maintenance. The West City fire department is asking what time the reservoir will be filled.
RESERVOIR
PUMP
The 7.0m diameter tank is filled by pumping water into the tank. The water fills the tank through a 55.0m long. 0.07m diameter pipe connected to the wall at the base of
the tank, The pipe has a Darcy-Weisbach friction factor of 0.04. The fire department has specified that the tank needs to be filled to 2.0m. The pump maintains a constant
discharge pressure of 30kPa
You write the following emal, inputting each value to 1 decimal place (without units), and rounding the time the tank will b hilled the nearest 30 minutes.
Hi James
Thank you for reaching out. We will begin filling the tank tomorrow morning at 10 00am when the water truck is scheduled to arrive. The tank will take
m3 of water to the tank at an average
hours to fill, and wil be completed by
pm. For reference, we will add
flow rate of
Please let me know if you have anny question
Thank you
West City Water Department
Transcribed Image Text:A large cylindrical reservoir needs to be filled with water after it was drained for maintenance. The West City fire department is asking what time the reservoir will be filled. RESERVOIR PUMP The 7.0m diameter tank is filled by pumping water into the tank. The water fills the tank through a 55.0m long. 0.07m diameter pipe connected to the wall at the base of the tank, The pipe has a Darcy-Weisbach friction factor of 0.04. The fire department has specified that the tank needs to be filled to 2.0m. The pump maintains a constant discharge pressure of 30kPa You write the following emal, inputting each value to 1 decimal place (without units), and rounding the time the tank will b hilled the nearest 30 minutes. Hi James Thank you for reaching out. We will begin filling the tank tomorrow morning at 10 00am when the water truck is scheduled to arrive. The tank will take m3 of water to the tank at an average hours to fill, and wil be completed by pm. For reference, we will add flow rate of Please let me know if you have anny question Thank you West City Water Department
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Types of Composite
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning