A COD test was carried out on a batik factory wastewater. The relevant information is as follows, Volume of potassium dichromate standard solution 0.1N Volume of wastewater sample Wastcwater sample dilution Fe" standard solution Volume of Fe“ standard solution needed for wastewater sample Volume of Fe" standard solution needed for distilled water 10.0 mL %3D 20.0 mL 10X %3| %3D 0.JN 21 13.55 mL 34.70 mL Calculate the COD value for the batik factory wastewater.
A COD test was carried out on a batik factory wastewater. The relevant information is as follows, Volume of potassium dichromate standard solution 0.1N Volume of wastewater sample Wastcwater sample dilution Fe" standard solution Volume of Fe“ standard solution needed for wastewater sample Volume of Fe" standard solution needed for distilled water 10.0 mL %3D 20.0 mL 10X %3| %3D 0.JN 21 13.55 mL 34.70 mL Calculate the COD value for the batik factory wastewater.
Solid Waste Engineering
3rd Edition
ISBN:9781305635203
Author:Worrell, William A.
Publisher:Worrell, William A.
Chapter5: Separation Processes
Section: Chapter Questions
Problem 5.32P
Related questions
Question
Wastewater Engineering civil engineering (11)
![A COD test was carried out on a batik factory wastewater. The relevant information
is as follows,
Volume of potassium dichromate standard solution (0.1N
Volume of wastewater samnple
Wastcwater sample dilution
Fe2* standard solution
Volume of Fe“" standard solution needed for wastewater sample
Volume of Fe“ standard solution needed for distilled water
10.0 mL
20.0 mL
%3D
10X
0.1N
13.55 mL
34.70 mL
Calculate the COD value for the batik factory wastewater.](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F31661b59-6507-4291-b2c5-636b7faf3641%2F03e746c8-5e09-4836-81f4-67e5ac679076%2Fm1hy56h_processed.jpeg&w=3840&q=75)
Transcribed Image Text:A COD test was carried out on a batik factory wastewater. The relevant information
is as follows,
Volume of potassium dichromate standard solution (0.1N
Volume of wastewater samnple
Wastcwater sample dilution
Fe2* standard solution
Volume of Fe“" standard solution needed for wastewater sample
Volume of Fe“ standard solution needed for distilled water
10.0 mL
20.0 mL
%3D
10X
0.1N
13.55 mL
34.70 mL
Calculate the COD value for the batik factory wastewater.
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Solid Waste Engineering](https://www.bartleby.com/isbn_cover_images/9781305635203/9781305635203_smallCoverImage.gif)
Solid Waste Engineering
Civil Engineering
ISBN:
9781305635203
Author:
Worrell, William A.
Publisher:
Cengage Learning,
![Solid Waste Engineering](https://www.bartleby.com/isbn_cover_images/9781305635203/9781305635203_smallCoverImage.gif)
Solid Waste Engineering
Civil Engineering
ISBN:
9781305635203
Author:
Worrell, William A.
Publisher:
Cengage Learning,