A built-up laced column of overall square cross-section, 300 mm size has been formed by placing four angles of ISA 50 x 50 x 6 mm at the corners of the square. If the effective height of column is 10 m, then calculate the load carrying capacity of the column. Also, check the lacing system for safety against: (i) Local buckling of column angles. (ii) Strength of lacing bars in tension and compression against shear load. (iii) Strength of M20 bolts of grade 4.6, check safety of bolt. Lacing system consist of 60 x 10 mm flat bars arranged in a single laced system and inclined to the axis of the column at an angle of 45° kL/r for (MPa) 164 153 135 125 111 98 86 40 50 60 70 80 90 100 145 50 For ISA 50 x 50 x 6 mm, area = 568 mm?, I, =I, = 12.9 x 104 mm4, 14.5 mm, Tmin = 15.1 mm.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
1
Q.7 (a) A built-up laced column of overall square cross-section, 300 mm size has been formed
by placing four angles of ISA 50 x 50 x 6 mm at the corners of the square. If the effective
height of column is 10 m, then calculate the load carrying capacity of the column. Also,
check the lacing system for safety against:
(i) Local buckling of column angles.
(ii) Strength of lacing bars in tension and compression against shear load.
(iii) Strength of M20 bolts of grade 4.6, check safety of bolt.
Lacing system consist of 60 x 10 mm flat bars arranged in a single laced system and
inclined to the axis of the column at an angle of 45°
kL./r
fot (MPa) 164 153 135 125 111 98 86
40
50
60
70
80 90 100 145
50
For ISA 50 x 50 x 6 mm, area =
568 mm2, I,
12.9 x 104 mm,
Cy
14.5 mm,
%3D
rmin = 15.1 mm.
%3D
Transcribed Image Text:Q.7 (a) A built-up laced column of overall square cross-section, 300 mm size has been formed by placing four angles of ISA 50 x 50 x 6 mm at the corners of the square. If the effective height of column is 10 m, then calculate the load carrying capacity of the column. Also, check the lacing system for safety against: (i) Local buckling of column angles. (ii) Strength of lacing bars in tension and compression against shear load. (iii) Strength of M20 bolts of grade 4.6, check safety of bolt. Lacing system consist of 60 x 10 mm flat bars arranged in a single laced system and inclined to the axis of the column at an angle of 45° kL./r fot (MPa) 164 153 135 125 111 98 86 40 50 60 70 80 90 100 145 50 For ISA 50 x 50 x 6 mm, area = 568 mm2, I, 12.9 x 104 mm, Cy 14.5 mm, %3D rmin = 15.1 mm. %3D
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Sectioning basics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning