(a) A three-phase transposed single line is composed of one Aluminium conductor steel- reinforced (ACSR) with the specification of 1,431,000-cmil and 47/7-Bobolink's conductor type per phase with horizontal spacing of 11 m as shown in Figure Q4(a)(i). The conductors have a diameter of 3.625cm and geometric mean radius (GMR) of 1.439cm. The link is to be replaced by a three-conductor bundled of ACSR with the specification of 477,000-cmil and 26/7-Hawk's conductor type per phase with horizontal spacing of 14m as measured from the center of the bundles as shown in Figure Q4(a)(ii). a b. D12 = 11 m- D23 = 11 m- D13 = 22 m- (i) 45 D12 14 m D23 14 m- D13 = 28 m (ii) gure Q4(a): Conductor layout of three phase transmission line (i) single conductor (iüi) three-bundles conductors (i) Three-conductor's bundles have a diameter of 2.1793 cm and GMR of 0.8839 cm. The spacing between the conductors in the bundle is 45 cm. Compare between the individual and three-conductor bundled for three phase transmission line and include the justification of the parameter changes based on the percentage change in the inductance.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
I need the answer as soon as possible
(a) A three-phase transposed single line is composed of one Aluminium conductor steel-
reinforced (ACSR) with the specification of 1,431,000-cmil and 47/7-Bobolink's
conductor type per phase with horizontal spacing of 11 m as shown in Figure Q4(a)(i).
The conductors have a diameter of 3.625cm and geometric mean radius (GMR) of
1.439cm. The link is to be replaced by a three-conductor bundled of ACSR with the
specification of 477,000-cmil and 26/7-Hawk's conductor type per phase with
horizontal spacing of 14m as measured from the center of the bundles as shown in
Figure Q4(a)(ii).
a
D12 = 11 m
D23
= 11 m
D13 = 22 m-
(i)
O,0
45
D12 = 14 m-
D23 14 m-
D13
28 m
(ii)
Figure Q4(a): Conductor layout of three phase transmission line (i) single conductor (ii)
three-bundles conductors
(i)
Three-conductor's bundles have a diameter of 2.1793 cm and GMR of 0.8839
cm. The spacing between the conductors in the bundle is 45 cm. Compare
between the individual and three-conductor bundled for three phase transmission
line and include the justification of the parameter changes based on the
percentage change in the inductance.
Transcribed Image Text:(a) A three-phase transposed single line is composed of one Aluminium conductor steel- reinforced (ACSR) with the specification of 1,431,000-cmil and 47/7-Bobolink's conductor type per phase with horizontal spacing of 11 m as shown in Figure Q4(a)(i). The conductors have a diameter of 3.625cm and geometric mean radius (GMR) of 1.439cm. The link is to be replaced by a three-conductor bundled of ACSR with the specification of 477,000-cmil and 26/7-Hawk's conductor type per phase with horizontal spacing of 14m as measured from the center of the bundles as shown in Figure Q4(a)(ii). a D12 = 11 m D23 = 11 m D13 = 22 m- (i) O,0 45 D12 = 14 m- D23 14 m- D13 28 m (ii) Figure Q4(a): Conductor layout of three phase transmission line (i) single conductor (ii) three-bundles conductors (i) Three-conductor's bundles have a diameter of 2.1793 cm and GMR of 0.8839 cm. The spacing between the conductors in the bundle is 45 cm. Compare between the individual and three-conductor bundled for three phase transmission line and include the justification of the parameter changes based on the percentage change in the inductance.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Coulomb's law
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,