(a) A 110 MVA, 55 kV three phase generator has a subtransient reactance of 8%. The generator supplies one motor over a transmission line having transformers at both ends as shown in Fig. The motor have rated input of 100 MVA 20 kV with 7% subtransient reactance. The rating of the sending end transformer, T, is 80 MVA, 200 kV / 35 kV (A- Y) with leakage reactanc 15%. Transformer T2 at the receiving end has 75 MVA, 200 kV /20 kV (Y-A). The leakage reactance of T2 is 10%. The line lengt 13 km and the series reactance of the line is 14 ohms/km. Draw the reactance diagram with all reactance marked in p.u. Choc 130 MVA and 40 kV as the base values. T2 Motor Generator T1 YE 3A Fwww

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.44P: A 130-MVA,13.2-kV three-phase generator, which has a positive-sequence reactance of 1.5 per unit on...
icon
Related questions
Question
Solve it fast plz
(a) A 110 MVA, 55 kV three phase generator has a subtransient reactance of 8%. The generator supplies one motor over a
transmission line having transformers at both ends as shown in Fig. The motor have rated input of 100 MVA 20 kV with 7%
subtransient reactance. The rating of the sending end transformer, T, is 80 MVA, 200 kV/ 35 kV (A- Y) with leakage reactance of
15%. Transformer T2 at the receiving end has 75 MVA, 200 kV /20 kV (Y-A ). The leakage reactance of T2 is 10%. The line length is
13 km and the series reactance of the line is 14 ohms/km. Draw the reactance diagram with all reactance marked in p.u. Choose
130 MVA and 40 kV as the base values.
T2
Motor
Generator
T1
YS
Δ
Transcribed Image Text:(a) A 110 MVA, 55 kV three phase generator has a subtransient reactance of 8%. The generator supplies one motor over a transmission line having transformers at both ends as shown in Fig. The motor have rated input of 100 MVA 20 kV with 7% subtransient reactance. The rating of the sending end transformer, T, is 80 MVA, 200 kV/ 35 kV (A- Y) with leakage reactance of 15%. Transformer T2 at the receiving end has 75 MVA, 200 kV /20 kV (Y-A ). The leakage reactance of T2 is 10%. The line length is 13 km and the series reactance of the line is 14 ohms/km. Draw the reactance diagram with all reactance marked in p.u. Choose 130 MVA and 40 kV as the base values. T2 Motor Generator T1 YS Δ
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Type of method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning