(a) A 110 MVA, 55 kV three phase generator has a subtransient reactance of 8%. The generator supplies one motor over a transmission line having transformers at both ends as shown in Fig. The motor have rated input of 100 MVA 20 kV with 7% subtransient reactance. The rating of the sending end transformer, T, is 80 MVA, 200 kV / 35 kV (A- Y) with leakage reactanc 15%. Transformer T2 at the receiving end has 75 MVA, 200 kV /20 kV (Y-A). The leakage reactance of T2 is 10%. The line lengt 13 km and the series reactance of the line is 14 ohms/km. Draw the reactance diagram with all reactance marked in p.u. Choc 130 MVA and 40 kV as the base values. T2 Motor Generator T1 YE 3A Fwww

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Solve it fast plz
(a) A 110 MVA, 55 kV three phase generator has a subtransient reactance of 8%. The generator supplies one motor over a
transmission line having transformers at both ends as shown in Fig. The motor have rated input of 100 MVA 20 kV with 7%
subtransient reactance. The rating of the sending end transformer, T, is 80 MVA, 200 kV/ 35 kV (A- Y) with leakage reactance of
15%. Transformer T2 at the receiving end has 75 MVA, 200 kV /20 kV (Y-A ). The leakage reactance of T2 is 10%. The line length is
13 km and the series reactance of the line is 14 ohms/km. Draw the reactance diagram with all reactance marked in p.u. Choose
130 MVA and 40 kV as the base values.
T2
Motor
Generator
T1
YS
Δ
Transcribed Image Text:(a) A 110 MVA, 55 kV three phase generator has a subtransient reactance of 8%. The generator supplies one motor over a transmission line having transformers at both ends as shown in Fig. The motor have rated input of 100 MVA 20 kV with 7% subtransient reactance. The rating of the sending end transformer, T, is 80 MVA, 200 kV/ 35 kV (A- Y) with leakage reactance of 15%. Transformer T2 at the receiving end has 75 MVA, 200 kV /20 kV (Y-A ). The leakage reactance of T2 is 10%. The line length is 13 km and the series reactance of the line is 14 ohms/km. Draw the reactance diagram with all reactance marked in p.u. Choose 130 MVA and 40 kV as the base values. T2 Motor Generator T1 YS Δ
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Type of method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,