A 6.6 kV, 3-phase, star-connected turbo-alternator of synchronous reactance 0.5 ohm/phase is applying 40 MVA at 0.8 lagging p.f. to a large system. If the steam supply is suddenly cut off, explain what takes place and determine the current the machine will then carry. Neglect losses.
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
A 6.6 kV, 3-phase, star-connected turbo-alternator of synchronous reactance 0.5
ohm/phase is applying 40 MVA at 0.8 lagging p.f. to a large system. If the steam
supply is suddenly cut off, explain what takes place and determine the current the
machine will then carry. Neglect losses.
Step by step
Solved in 2 steps with 2 images