A 50HZ, synchronous generator is connected to infinite bus through a transmission line. The pu reactance of generator and transformer line are j0.4 and j0.2 respectively. The no load Voltage of generator is 1.2pu and infinite bus=Ipu. Inertia constant is 4MJ/MVA. Determine frequency of natural oscillation if generator is loaded frequency to 50% of P Ka) 1.31 Hz, 1.09 Hz (c) 1.01 Hz, 1.09 Hz and 80% of P and small disturbance is applied max max (b) 1.31 Hz, 1.29 Hz (d} 1.01 Hz, 1.29 Hz
A 50HZ, synchronous generator is connected to infinite bus through a transmission line. The pu reactance of generator and transformer line are j0.4 and j0.2 respectively. The no load Voltage of generator is 1.2pu and infinite bus=Ipu. Inertia constant is 4MJ/MVA. Determine frequency of natural oscillation if generator is loaded frequency to 50% of P Ka) 1.31 Hz, 1.09 Hz (c) 1.01 Hz, 1.09 Hz and 80% of P and small disturbance is applied max max (b) 1.31 Hz, 1.29 Hz (d} 1.01 Hz, 1.29 Hz
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Concept explainers
KVL and KCL
KVL stands for Kirchhoff voltage law. KVL states that the total voltage drops around the loop in any closed electric circuit is equal to the sum of total voltage drop in the same closed loop.
Sign Convention
Science and technology incorporate some ideas and techniques of their own to understand a system skilfully and easily. These techniques are called conventions. For example: Sign conventions of mirrors are used to understand the phenomenon of reflection and refraction in an easier way.
Question
1
![A 50HZ, synchronous generator is connected to infinite bus through a transmission line. The pu reactance
of generator and transformer line are j0.4 and j0.2 respectively. The no load Voltage of generator is 1.2pu
and infinite bus-lpu. Inertia constant is 4MJ/MVA. Determine frequency of natural oscillation if generator
is loaded frequency to 50% ofP,
Ka) 1.31 Hz, 1.09 Hz
(c) 1.01 Hz, 1.09 Hz
ubiun
and 80% of P, and small disturbance is applied
max
max
(b) 1.31 Hz, 1.29 Hz
(d) 1.01 Hz, 1.29 Hz](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F94b564a8-f45d-48ff-8048-ce8e3d6750f7%2F53fd425c-eb2d-46cb-8fb1-1ac5b488aa75%2F2majzjs_processed.jpeg&w=3840&q=75)
Transcribed Image Text:A 50HZ, synchronous generator is connected to infinite bus through a transmission line. The pu reactance
of generator and transformer line are j0.4 and j0.2 respectively. The no load Voltage of generator is 1.2pu
and infinite bus-lpu. Inertia constant is 4MJ/MVA. Determine frequency of natural oscillation if generator
is loaded frequency to 50% ofP,
Ka) 1.31 Hz, 1.09 Hz
(c) 1.01 Hz, 1.09 Hz
ubiun
and 80% of P, and small disturbance is applied
max
max
(b) 1.31 Hz, 1.29 Hz
(d) 1.01 Hz, 1.29 Hz
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 1 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Fundamentals of Electric Circuits](https://www.bartleby.com/isbn_cover_images/9780078028229/9780078028229_smallCoverImage.gif)
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
![Electric Circuits. (11th Edition)](https://www.bartleby.com/isbn_cover_images/9780134746968/9780134746968_smallCoverImage.gif)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
![Engineering Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780078028151/9780078028151_smallCoverImage.gif)
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,