A 440-V, 3-phase, 8-pole, 50-Hz star-connected induction motor is given. The equivalent circuit of RI -0.1ohm, R2-0.1/s ohm; x1 x'2 j0.5 ohm, Re-100 ohm, xm-j20 ohm. The short-circuit test is conducted with a locked rotor and a line current of 80 A. The 'open-circuit test is conducted by supplying the primary winding at rated voltage and at the same time driving the rotor in the same direction as the rotating field, at synchronous speed; s=0. Detemine: (a) the line voltage and power factor on the short-circuit test; (b) the line current and power factor on the 'open-circuit test; (c) the equivalent circuit per-phase if these tests were analyzed on an approximate basis; i.e. neglecting the magnetizing branch when analyzing the s.c. test and neglecting the series leakage impedances for analysis of the o.c. test

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
i need the answer quickly
A 440-V, 3-phase, 8-pole, 50-Hz star-connected induction motor is given. The
equivalent circuit of RI -0.lohm, R2-0.1/s ohm; x1 x'2-jo.5 ohm,
Re-100 ohm, xm-j20 ohm. The short-circuit test is conducted with a locked rotor
and a line current of 80 A. The 'open-circuit' test is conducted by supplying the
primary winding at rated voltage and at the same time driving the rotor in the same
direction as the rotating field, at synchronous speed; s 0. Determine:
(a) the line voltage and power factor on the short-circuit test;
(b) the line current and power factor on the 'open-circuit' test;
(c) the equivalent circuit per-phase if these tests were analyzed on an approximate
basis; i.e. neglecting the magnetizing branch when analyzing the s.c. test and
neglecting the series leakage impedances for analysis of the o.c. test
Transcribed Image Text:A 440-V, 3-phase, 8-pole, 50-Hz star-connected induction motor is given. The equivalent circuit of RI -0.lohm, R2-0.1/s ohm; x1 x'2-jo.5 ohm, Re-100 ohm, xm-j20 ohm. The short-circuit test is conducted with a locked rotor and a line current of 80 A. The 'open-circuit' test is conducted by supplying the primary winding at rated voltage and at the same time driving the rotor in the same direction as the rotating field, at synchronous speed; s 0. Determine: (a) the line voltage and power factor on the short-circuit test; (b) the line current and power factor on the 'open-circuit' test; (c) the equivalent circuit per-phase if these tests were analyzed on an approximate basis; i.e. neglecting the magnetizing branch when analyzing the s.c. test and neglecting the series leakage impedances for analysis of the o.c. test
Expert Solution
steps

Step by step

Solved in 4 steps with 3 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,