A 400 mm x 400 mm column carries a total dead load of 1150 kN and a total live load of 770 kN. The column is to be supported by a rectangular spread footing having thickness of 675 mm whose width is limited to 3 m. The net soil bearing capacity of the soil is 215 kPa. For footing, use f'c = 24 MPa and for column, use f'c = 20.7 MPa. Use fy = 414 MPa for all steel bars. Use 75mm concrete cover. 11. Determine the length of the footing. 12. Determine wide beam shear stress at the critical section. 13. Determine the punching shear stress at the critical section. 14. Design the reinforcements using 25 mm bars, determine the number of reinforcements along the long direction. 15. Design the reinforcements using 25 mm bars, determine the number of reinforcements along the short direction.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
icon
Concept explainers
Question
A 400 mm x 400 mm column carries a total dead
load of 1150 kN and a total live load of 770 kN. The
column is to be supported by a rectangular spread
footing having thickness of 675 mm whose width is
limited to 3 m. The net soil bearing capacity of the
soil is 215 kPa. For footing, use f'c = 24 MPa and
for column, use f'c = 20.7 MPa. Use fy = 414 MPa
for all steel bars. Use 75mm concrete cover.
11. Determine the length of the footing.
12. Determine wide beam shear stress at the
critical section.
13. Determine the punching shear stress at the
critical section.
14. Design the reinforcements using 25 mm bars,
determine the number of reinforcements along the
long direction.
15. Design the reinforcements using 25 mm bars,
determine the number of reinforcements along the
short direction.
Transcribed Image Text:A 400 mm x 400 mm column carries a total dead load of 1150 kN and a total live load of 770 kN. The column is to be supported by a rectangular spread footing having thickness of 675 mm whose width is limited to 3 m. The net soil bearing capacity of the soil is 215 kPa. For footing, use f'c = 24 MPa and for column, use f'c = 20.7 MPa. Use fy = 414 MPa for all steel bars. Use 75mm concrete cover. 11. Determine the length of the footing. 12. Determine wide beam shear stress at the critical section. 13. Determine the punching shear stress at the critical section. 14. Design the reinforcements using 25 mm bars, determine the number of reinforcements along the long direction. 15. Design the reinforcements using 25 mm bars, determine the number of reinforcements along the short direction.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Load and resistance factor design
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning