A 4-KV A,200/400 V single phase transformer has the following open circuit test and short circuit test Results: O.C.T at low voltage side: 200 V, 0.7A, 65 W PRC S.C.T low voltage windings are short circuited: 15 V, 10 A, 75 W Cupper Lusing 1. Calculate the series impedance of the transformer and find Rc and Xm. Draw the equivalent circuit referred to the high voltage side. 2. Find the full load efficiency at unity power factor. PP: 1 2001460 0:45 Full load voltage regulation at 0.8 power factor lagging. A Draw the phasor diagram when the transformer operate at full load 0.8 lagging pf S-4x10²
A 4-KV A,200/400 V single phase transformer has the following open circuit test and short circuit test Results: O.C.T at low voltage side: 200 V, 0.7A, 65 W PRC S.C.T low voltage windings are short circuited: 15 V, 10 A, 75 W Cupper Lusing 1. Calculate the series impedance of the transformer and find Rc and Xm. Draw the equivalent circuit referred to the high voltage side. 2. Find the full load efficiency at unity power factor. PP: 1 2001460 0:45 Full load voltage regulation at 0.8 power factor lagging. A Draw the phasor diagram when the transformer operate at full load 0.8 lagging pf S-4x10²
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Question
please answer the following question,
ignore whats written in a blue pen .
..

Transcribed Image Text:A 4-KV A,200/400 V single phase transformer has the following open circuit test and short circuit test
Results:
O.C.T at low voltage side: 200 V, 0.7A, 65 W
PRC
S.C.T low voltage windings are short circuited: 15 V, 10 A, 75 W
Cupper Lussing
1. Calculate the series impedance of the transformer and find Rc and Xm. Draw the equivalent circuit
referred to the high voltage side.
2. Find the full load efficiency at unity power factor.
Full load voltage regulation at 0.8 power factor lagging.
Draw the phasor diagram when the transformer operate at full load 0.8 lagging pf
5=4x10²
2001460
Pf: 1 0=45
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 5 steps with 5 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education

Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education

Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON

Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,