A 3-phase,50Hz, 4-pole, Y-connected alternator has 6 slots per pole per phase. The armature has double layers winding. The windings are arranged as 5 conductors per layer. The coil pitch is 5/6th of the full pitch and the flux per pole is o.o5Wb. Determine the voltag per phase
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
A 3-phase,50Hz, 4-pole, Y-connected alternator has 6 slots per pole per phase. The armature has double layers winding. The windings are arranged as 5 conductors per layer. The coil pitch is 5/6th of the full pitch and the flux per pole is o.o5Wb. Determine the voltag per phase
Step by step
Solved in 5 steps with 4 images