4-pole, 3-phase, 50-Hz, star-connected alternator has 60 slots, with 4 conductors per slot. Coils are short-pitched by 3 slots. If the phase spread is 60º, find the line voltage induced for a flux per pole of 0.943 Wb distributed sinusoidally in space. All the turns per phase is in series
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
A 4-pole, 3-phase, 50-Hz, star-connected
alternator has 60 slots, with 4 conductors per
slot. Coils are short-pitched by 3 slots. If the
phase spread is 60º, find the line voltage
induced for a flux per pole of 0.943 Wb
distributed sinusoidally in space. All the turns
per phase is in series.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 1 images