A 2m x 3m footing constructed on a sand deposit (as shown in the Figure below) is subjected to centric vertical loading at a depth of 1.5m below the ground surface. Energy-corrected SPT Noo values from the field are given below. Assume c' = 0, y = 18.5 kN/m, Vat = 19.5 kN/m, %3D Assuming Factor of Safety = 3, compare the gross allowable load for the following scenarios. (a) When the ground water table is located at the ground surface. (b) When the ground water table is located 0.5 m below the ground surface. (c) When the ground water table is located at the base of the footing. (d) When the ground water table is located 1m below the base of the footing. (e) When the ground water table is located 5 m below the base of the footing. Ground water D able Casel D Casell Yaturated unit weight Depth (m) Neo 1.5 3.0 4.5 6.0 10 7.5 10 9.0

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
A 2m x 3m footing constructed on a sand deposit (as shown in the Figure below)
is subjected to centric vertical loading at a depth of 1.5m below the ground surface.
Energy-corrected SPT Noo values from the field are given below. Assume c' = 0, y
= 18.5 kN/m, Vat = 19.5 kN/m,
%3D
Assuming Factor of Safety = 3, compare the gross allowable load for the following
scenarios.
(a) When the ground water table is located at the ground surface.
(b) When the ground water table is located 0.5 m below the ground surface.
(c) When the ground water table is located at the base of the footing.
(d) When the ground water table is located 1m below the base of the footing.
(e) When the ground water table is located 5 m below the base of the footing.
Ground water
D
able
Casel
D
Casell
Yaturated
unit weight
Depth (m)
Neo
1.5
3.0
4.5
6.0
10
7.5
10
9.0
Transcribed Image Text:A 2m x 3m footing constructed on a sand deposit (as shown in the Figure below) is subjected to centric vertical loading at a depth of 1.5m below the ground surface. Energy-corrected SPT Noo values from the field are given below. Assume c' = 0, y = 18.5 kN/m, Vat = 19.5 kN/m, %3D Assuming Factor of Safety = 3, compare the gross allowable load for the following scenarios. (a) When the ground water table is located at the ground surface. (b) When the ground water table is located 0.5 m below the ground surface. (c) When the ground water table is located at the base of the footing. (d) When the ground water table is located 1m below the base of the footing. (e) When the ground water table is located 5 m below the base of the footing. Ground water D able Casel D Casell Yaturated unit weight Depth (m) Neo 1.5 3.0 4.5 6.0 10 7.5 10 9.0
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning