5. Design a PLC program and prepare a typical I/O connection diagram and ladder logic program that will correctly execute the hardwired control circuit in Figure 6-79. Assume: PB1 pushbutton used is an NO type. PB2 pushbutton used is an NC type. PS1 pressure switch used is an NO type. LS1 limit switch used has only one set of NC contacts.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
e 6-77, and
OL contact is hardwired.
ng 1 be true?
ng 2 be true?
5. Design a PLC program and prepare a typical I/O
connection diagram and ladder logic program that
will correctly execute the hardwired control circuit
true?
in Figure 6-79.
Assume: PB1 pushbutton used is an NO type.
PB2 pushbutton used is an NC type.
PS1 pressure switch used is an NO type.
LS1 limit switch used has only one set of
state
state
tored to the
NC contacts.
cally come
L1
L2
Start
Stop
PB 1
PB 2
and all three
CR1
must occur
ed state?
at addresses
e will the
)?
pical I/O
rogram that
PL1
CR1-1
CR1-2
SOL 1
PS1
CR2
Outputs
L2
CR2-1
LS1
SOL 2
HH
PL1
S1
CR2-2
SOL 3
/10
(PL2
PL2
G.79
Hardwired control circuit, for Problem 5.
Transcribed Image Text:e 6-77, and OL contact is hardwired. ng 1 be true? ng 2 be true? 5. Design a PLC program and prepare a typical I/O connection diagram and ladder logic program that will correctly execute the hardwired control circuit true? in Figure 6-79. Assume: PB1 pushbutton used is an NO type. PB2 pushbutton used is an NC type. PS1 pressure switch used is an NO type. LS1 limit switch used has only one set of state state tored to the NC contacts. cally come L1 L2 Start Stop PB 1 PB 2 and all three CR1 must occur ed state? at addresses e will the )? pical I/O rogram that PL1 CR1-1 CR1-2 SOL 1 PS1 CR2 Outputs L2 CR2-1 LS1 SOL 2 HH PL1 S1 CR2-2 SOL 3 /10 (PL2 PL2 G.79 Hardwired control circuit, for Problem 5.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Proportional, Integral, Derivative Controllers and their Combinations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,