3. A single-phase 30KVA, 2000V/200V, 60HZ distribution transforme transformer at the load end of a 2000V feeder whose series imped: equivalent series reactance of the transformer is j10 ohms refer (primary) side. The transformer is delivering rated load at 0.9 pot rated secondary voltage. Neglecting the transformer exciting curr- determine the apparent power delivered to the sending end of the
3. A single-phase 30KVA, 2000V/200V, 60HZ distribution transforme transformer at the load end of a 2000V feeder whose series imped: equivalent series reactance of the transformer is j10 ohms refer (primary) side. The transformer is delivering rated load at 0.9 pot rated secondary voltage. Neglecting the transformer exciting curr- determine the apparent power delivered to the sending end of the
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.16P: A single-phase, 50-kVA,2400/240-V,60-Hz distribution transformer has the following parameters:...
Related questions
Question
Power system class

Transcribed Image Text:3. A single-phase 30KVA, 2000V/200V, 60Hz distribution transformer is used as a step-down
transformer at the load end of a 2000V feeder whose series impedance is 1+j20 ohms. The
equivalent series reactance of the transformer is j10 ohms referred to the high-voltage
(primary) side. The transformer is delivering rated load at 0.9 power factor lagging and at
rated secondary voltage. Neglecting the transformer exciting current and series resistance,
determine the apparent power delivered to the sending end of the feeder.
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 2 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning

Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning