2.10 A pressure sensor consisting of a diaphragm with strain gauges bonded to its surface has the following information in its specification: Ranges: 0 to 1400 kPa, 0 to 35 000 kPa Non-linearity error: 0.15% of full range Hysteresis error: 0.05% of full range What is the total error due to non-linearity and hysteresis for a reading of 1000 kPa on the 0 to 1400 kPa range?

icon
Related questions
Question

finals answer= 2.8kPa

2.10 A pressure sensor consisting of a diaphragm with strain gauges bonded to its
surface has the following information in its specification:
Ranges: 0 to 1400 kPa, 0 to 35 000 kPa
Non-linearity error: 0.15% of full range
Hysteresis error: 0.05% of full range
What is the total error due to non-linearity and hysteresis for a reading of 1000 kPa
on the 0 to 1400 kPa range?
Transcribed Image Text:2.10 A pressure sensor consisting of a diaphragm with strain gauges bonded to its surface has the following information in its specification: Ranges: 0 to 1400 kPa, 0 to 35 000 kPa Non-linearity error: 0.15% of full range Hysteresis error: 0.05% of full range What is the total error due to non-linearity and hysteresis for a reading of 1000 kPa on the 0 to 1400 kPa range?
Expert Solution
Step 1

Calculate the error due to the non linearity for a reading of 1000 kPa on 0 to 1400 kPa range.

Non linearity error eL=0.15% of full range.                               =0.15% of 1400                               =0.15100×1400                               =2.1 kPa