2.10 A pressure sensor consisting of a diaphragm with strain gauges bonded to its surface has the following information in its specification: Ranges: 0 to 1400 kPa, 0 to 35 000 kPa Non-linearity error: 0.15% of full range Hysteresis error: 0.05% of full range What is the total error due to non-linearity and hysteresis for a reading of 1000 kPa on the 0 to 1400 kPa range?
2.10 A pressure sensor consisting of a diaphragm with strain gauges bonded to its surface has the following information in its specification: Ranges: 0 to 1400 kPa, 0 to 35 000 kPa Non-linearity error: 0.15% of full range Hysteresis error: 0.05% of full range What is the total error due to non-linearity and hysteresis for a reading of 1000 kPa on the 0 to 1400 kPa range?
Related questions
Question
finals answer= 2.8kPa

Transcribed Image Text:2.10 A pressure sensor consisting of a diaphragm with strain gauges bonded to its
surface has the following information in its specification:
Ranges: 0 to 1400 kPa, 0 to 35 000 kPa
Non-linearity error: 0.15% of full range
Hysteresis error: 0.05% of full range
What is the total error due to non-linearity and hysteresis for a reading of 1000 kPa
on the 0 to 1400 kPa range?
Expert Solution

Step 1
Calculate the error due to the non linearity for a reading of 1000 kPa on 0 to 1400 kPa range.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps