2. The cantilever retaining wall retains a sol having a unit weight of 18kN/Cu.m. and an angle shearing resistance of 30o degrees. Unit weight of concrete is 25AN/cu.m. Neglect the effect of the soil at right side of the wall. 2.00 Determine the following a. Factor of safety against sliding if the coeficient of friction between the base and the foundation is 0.6 b. Maximum service moment at the stem per meter length of the wal. C If the stem is to be reinforced with 20mm diameter bars with centroid 85mm from the extreme concrete, what is the required spacing of the bars? Use fc= 24MPA and fy 345MPA. Use load factor of soil pressure1.7o.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
2. The cantilever retaining wall retains a soil having a unit weight of 18KN/cu.m. and an angle
shearing resistance of 30 degrees. Unit weight of concrete is 25KN/cu.m. Neglect the effect of
the soil at right side of the wall.
2.00
Determine the following
a. Factor of safety against sliding if the coefficient of friction between the base and the
foundation is 0.6
b. Maximum service moment at the stem per meter length of the wall.
c. If the stem is to be reinforced with 20mm diameter bars with centroid 85mm from the
extreme concrete, what is the required spacing of the bars? Use fc = 24MPA and fy =
345MPA. Use load factor of soil pressure 1.70.
Transcribed Image Text:2. The cantilever retaining wall retains a soil having a unit weight of 18KN/cu.m. and an angle shearing resistance of 30 degrees. Unit weight of concrete is 25KN/cu.m. Neglect the effect of the soil at right side of the wall. 2.00 Determine the following a. Factor of safety against sliding if the coefficient of friction between the base and the foundation is 0.6 b. Maximum service moment at the stem per meter length of the wall. c. If the stem is to be reinforced with 20mm diameter bars with centroid 85mm from the extreme concrete, what is the required spacing of the bars? Use fc = 24MPA and fy = 345MPA. Use load factor of soil pressure 1.70.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Retaining walls
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning