2. A 250 kVA, 480 V, 50 Hz, delta-connected alternator with a rated field current of 5 A was tested and the following test data were obtained: • Open circuit terminal voltage from OC test data is 540 V at the rated IF. Short circuit current from SC test data is 300 A at the rated If. •A dc current of 20A is flowing through any two stator armature terminals, when a DC voltage of 10 V was applied to two of the terminals. Evaluate the following from above tests data the armature resistance, the approximate synchronous reactance and voltage regulation at rated load and 0.7 pf lead.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
2. A 250 kVA, 480 V, 50 Hz, delta-connected alternator with a rated field current of 5 A was tested and the
following test data were obtained:
• Open circuit terminal voltage from OC test data is 540 V at the rated IF.
• Short circuit current from SC test data is 300 A at the rated IF.
• A dc current of 20A is flowing through any two stator armature terminals, when a DC voltage of 10
V was applied to two of the terminals.
Evaluate the following from above tests data the armature resistance, the approximate synchronous
reactance and voltage regulation at rated load and 0.7 pf lead.
Transcribed Image Text:2. A 250 kVA, 480 V, 50 Hz, delta-connected alternator with a rated field current of 5 A was tested and the following test data were obtained: • Open circuit terminal voltage from OC test data is 540 V at the rated IF. • Short circuit current from SC test data is 300 A at the rated IF. • A dc current of 20A is flowing through any two stator armature terminals, when a DC voltage of 10 V was applied to two of the terminals. Evaluate the following from above tests data the armature resistance, the approximate synchronous reactance and voltage regulation at rated load and 0.7 pf lead.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,