1/Power loss due to corona is: a. Inversely proportional to frequency. b. Proportional to frequency. c. Frequency does not effect. с. d. All these answers are wrong. 2/ We prefer High voltage DC (HVDC) transmission system than High Voltage AC transmission system according to the cost, when: a. The distance of the line is more than B00 km. b. The distance of the line is less than 300 km. c. The distance of the line is equal to 300 km. d. All the above answers are wrong. 3/ HVDC Transmission has lower corona losses than HVAC Transmission because: a. HVDC Transmission tower is less height than HVAC Transmission tower. b. HVDC Transmission system work with zero frequency than HVAC Transmission system of 50 Hz. c. HVDC Transmission currents is uniform distributed in the all cross section of the system conductors than HVAC Transmission due to skin effect. с. d. All of the above answers are wright.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter8: Symmetrical Components
Section: Chapter Questions
Problem 8.10P
icon
Related questions
icon
Concept explainers
Question
1/ Power loss due to corona is:
a. Inversely proportional to frequency.
b. Proportional to frequency.
c. Frequency does not effect.
d. All these answers are wrong.
2/ We prefer High voltage DC (HVDC) transmission system than High Voltage AC
transmission system according to the cost, when:
a. The distance of the line is more than B00 km.
b. The distance of the line is less than 300 km.
c. The distance of the line is equal to 300 km.
d. All the above answers are wrong.
3/ HVDC Transmission has lower corona losses than HVAC Transmission because:
a. HVDC Transmission tower is less height than HVAC Transmission tower.
b. HVDC Transmission system work with zero frequency than HVAC Transmission system of
50 Hz.
c. HVDC Transmission currents is uniform distributed in the all cross section of the
system conductors than HVAC Transmission due to skin effect.
d. All of the above answers are wright.
Transcribed Image Text:1/ Power loss due to corona is: a. Inversely proportional to frequency. b. Proportional to frequency. c. Frequency does not effect. d. All these answers are wrong. 2/ We prefer High voltage DC (HVDC) transmission system than High Voltage AC transmission system according to the cost, when: a. The distance of the line is more than B00 km. b. The distance of the line is less than 300 km. c. The distance of the line is equal to 300 km. d. All the above answers are wrong. 3/ HVDC Transmission has lower corona losses than HVAC Transmission because: a. HVDC Transmission tower is less height than HVAC Transmission tower. b. HVDC Transmission system work with zero frequency than HVAC Transmission system of 50 Hz. c. HVDC Transmission currents is uniform distributed in the all cross section of the system conductors than HVAC Transmission due to skin effect. d. All of the above answers are wright.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning