16-level safety high (LSH) installed in separator to prevent : a-Gas Blowby b-Liquid Carryover 17. Fla c- foam d-high pressure

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
16-level safety high (LSH) installed in separator to prevent:
a-Gas Blowby
b-Liquid Carryover
17- Flare or vent scrubbers
a-to discharge the gas
in separator are designed to:
b- safety issue
18- foaming can be expected in the separator where CO₂ is present in
a-1.5%
b-4-5%
c- 1-2 ppm
21- free water knockout used when
a- the amount of gas relatively high (b-small amount of gas
22- the best storage has used in refinery is
a- Floating roof tanks
c- foam
c- not given
20- when API Gravity 20 the Retention Time (min) in separator should be
0.5-1
b-4+
c-2
d- 3
19- Where foaming crude is present, retention times up to -----------this amount may be needed
a-three time
b- four time
c- two time
d- five time
c-Toxicity of the petroleum material
d-Using fixed-roof tanks along with the VRU system
abisin
b- external roof tank c- closed float roof tank
14ung all
d- more than 20%
25- The seam-to-seam length should not exceed the following:
a- Lss 5/3 Leff
b-Lss= 4/3 Leff
c- Lss 2 Leff
c-3
d-4
d-high pressure
d keep large slugs
c- bubble point pressure high d- nun of them
23- which one is correct statement
The design of storage tanks for crude oil, in general, careful consideration of the following important factors:
a- the distance between the storage location and city
b- the weather
rengas on.
30- which one in figure is overflow baffle :
a 1
b-2
24- For a group of wells (entire field), the total tank capacity should be adequate enough for
a-2-3 days'
b-4-5 days
c-minimum 3 days
d- nun of them
28- To remove the wax which accolated in separator internal should a provide
(a-steam
b-solvent
d-Fixed roof tanks
26- the weir component exists in :
a- three phase separator b- horizontal three phase separator
c- two phase separator d- all of them
This section contains 4 multiple choice questions. Each question has four choices only one or more may be correct.
27- The equipment on the surface cannot handle gas-liquid mixtures, due to:
Ca Pumps require gas-free liquid;
CB-Gas sales contracts generally require that the gas contain no free liquids;
(c Measurement devices for gases or liquids are highly inaccurate when another phase is present.
d- it needs to specify the phase of fluid before buy the equipments
d- Lss= 1.5 Leff
c-antiwax plate d- increase the separator temperature
%
29- Breathing losses occur in storage tank when vapors are expelled from a tank under one of the following conditions:
a The expansion due to increase the temperature of the existing vapors
b An expansion caused by barometric pressure changes
c- there is no VRU system
d- Release vapor from the storage tank when the normal operating pressure
77
Interlace Level
quid Lovel
Gas
OF
2
200
D
son
1
16
3
Transcribed Image Text:16-level safety high (LSH) installed in separator to prevent: a-Gas Blowby b-Liquid Carryover 17- Flare or vent scrubbers a-to discharge the gas in separator are designed to: b- safety issue 18- foaming can be expected in the separator where CO₂ is present in a-1.5% b-4-5% c- 1-2 ppm 21- free water knockout used when a- the amount of gas relatively high (b-small amount of gas 22- the best storage has used in refinery is a- Floating roof tanks c- foam c- not given 20- when API Gravity 20 the Retention Time (min) in separator should be 0.5-1 b-4+ c-2 d- 3 19- Where foaming crude is present, retention times up to -----------this amount may be needed a-three time b- four time c- two time d- five time c-Toxicity of the petroleum material d-Using fixed-roof tanks along with the VRU system abisin b- external roof tank c- closed float roof tank 14ung all d- more than 20% 25- The seam-to-seam length should not exceed the following: a- Lss 5/3 Leff b-Lss= 4/3 Leff c- Lss 2 Leff c-3 d-4 d-high pressure d keep large slugs c- bubble point pressure high d- nun of them 23- which one is correct statement The design of storage tanks for crude oil, in general, careful consideration of the following important factors: a- the distance between the storage location and city b- the weather rengas on. 30- which one in figure is overflow baffle : a 1 b-2 24- For a group of wells (entire field), the total tank capacity should be adequate enough for a-2-3 days' b-4-5 days c-minimum 3 days d- nun of them 28- To remove the wax which accolated in separator internal should a provide (a-steam b-solvent d-Fixed roof tanks 26- the weir component exists in : a- three phase separator b- horizontal three phase separator c- two phase separator d- all of them This section contains 4 multiple choice questions. Each question has four choices only one or more may be correct. 27- The equipment on the surface cannot handle gas-liquid mixtures, due to: Ca Pumps require gas-free liquid; CB-Gas sales contracts generally require that the gas contain no free liquids; (c Measurement devices for gases or liquids are highly inaccurate when another phase is present. d- it needs to specify the phase of fluid before buy the equipments d- Lss= 1.5 Leff c-antiwax plate d- increase the separator temperature % 29- Breathing losses occur in storage tank when vapors are expelled from a tank under one of the following conditions: a The expansion due to increase the temperature of the existing vapors b An expansion caused by barometric pressure changes c- there is no VRU system d- Release vapor from the storage tank when the normal operating pressure 77 Interlace Level quid Lovel Gas OF 2 200 D son 1 16 3
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The