12. A standard solution with known concentrations of tartaric acid and fumaric acid was prepared and measured using reversed phase liquld chromatography. The data for known concentrations is shown in the table below: Concentration (ppm) Peak Area Sample mobile phase N/A N/A tartaric acid 455 369 fumaric acid 125 249 A second solution containing 5.00 mL of an unknown concentration of tartaric acid was combined with 10.0 ml of 81.0 ppm of fumaric acid and diluted with water to 100.00 mL in a 100.00 ml volumetric flask. The chromatogram of this mixture produced peak areas of 244 and 125 for tartaric acid and fumaric acid, respectively. a. What type of calibration method is used in this analysis and how do you know? b. In this analysis, the stationary phase is: Circle Oner: POLAR NO POLAR C. By increasing the eluent strength of the mobile phase (making it more like the column polarity), how would the retention time of the analyte change in the analysis? Circle Ones INCREASE DECREASE d. Determine the concentration (in ppm) of tartaric acid in the unknown solution.

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question

Please answer this

12. A standard solution with known concentrations of tartaric acid and fumaric acid was prepared and
measured using reversed phase liquid chromatography. The data for known concentrations is shown in
the table below:
Concentration
Peak Area
Sample
(ppm)
mobile phase
N/A
N/A
tartaric acid
455
369
fumaric acid
125
249
A second solution containing 5.00 mL of an unknown concentration of tartaric acid was combined with
10.0 ml of 81.0 ppm of fumaric acid and diluted with water to 100.00 ml in a 100.00 ml volumetric
flask. The chromatogram of this mixture produced peak areas of 244 and 125 for tartaric acid and
fumaric acid, respectively.
a. What type of cąlibration method is used in this analysis and how do you know?
b. In this analysis, the stationary phase is: Circle Oner:
POLAR
NO POLAR
c. By increasing the eluent strength of the mobile phase (making it more like the column polarity), how
would the retention time of the analyte change in the analysis? Circle Ones
INCREASE
DECREASE
d. Determine the concentration (in ppm) of tartaric acid in the unknown solution.
Transcribed Image Text:12. A standard solution with known concentrations of tartaric acid and fumaric acid was prepared and measured using reversed phase liquid chromatography. The data for known concentrations is shown in the table below: Concentration Peak Area Sample (ppm) mobile phase N/A N/A tartaric acid 455 369 fumaric acid 125 249 A second solution containing 5.00 mL of an unknown concentration of tartaric acid was combined with 10.0 ml of 81.0 ppm of fumaric acid and diluted with water to 100.00 ml in a 100.00 ml volumetric flask. The chromatogram of this mixture produced peak areas of 244 and 125 for tartaric acid and fumaric acid, respectively. a. What type of cąlibration method is used in this analysis and how do you know? b. In this analysis, the stationary phase is: Circle Oner: POLAR NO POLAR c. By increasing the eluent strength of the mobile phase (making it more like the column polarity), how would the retention time of the analyte change in the analysis? Circle Ones INCREASE DECREASE d. Determine the concentration (in ppm) of tartaric acid in the unknown solution.
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY