11.a. Which of the following is a point where a grounding electrode conductor connection must be made in the communication system? A. The flexible nonmetallic power service raceway B. The grounding electrode conductor or metal enclosure for a grounding electrode conductor C. The space opposite the service equipment enclosure D. The grounded exterior metal water piping system within six feet of the point where it enters the building 11.b. The equipment grounding conductor of a pump motor for a swimming pool must be grounded with a solid copper conductor that's no smaller than A. AWG 8. B. AWG 12. C. AWG 10. D. AWG 6.
Protection System
A system that protects electrical systems from faults by isolating the problematic part from the remainder of the system, preventing power from being cut from healthy elements, improving system dependability and efficiency is the protection system. Protection devices are the equipment that are utilized to implement the protection system.
Predictive Maintenance System
Predictive maintenance technologies are designed to assist in determining the state of in-service equipment so that maintenance can be scheduled. Predictive maintenance is the application of information; proactive maintenance approaches examine the condition of equipment and anticipate when it should maintain. The purpose of predictive maintenance is to forecast when equipment will fail (depending on a variety of parameters), then prevent the failure through routine and corrective maintenance.Condition monitoring is the continual monitoring of machines during process conditions to maintain optimal machine use, which is necessary for predictive maintenance. There are three types of condition monitoring: online, periodic, and remote. Finally, remote condition monitoring allows the equipment observed from a small place and data supplied for analysis.
Preventive Maintenance System
To maintain the equipment and materials on a regular basis in order to maintain those running conditions and reduce unnecessary shutdowns due to unexpected equipment failure is called Preventive Maintenance (PM).
11.a. Which of the following is a point where a grounding electrode conductor connection must be made in
the communication system?
A. The flexible nonmetallic power service raceway
B. The grounding electrode conductor or metal enclosure for a grounding electrode conductor
C. The space opposite the service equipment enclosure
D. The grounded exterior metal water piping system within six feet of the point where it enters the building
11.b. The equipment grounding conductor of a pump motor for a swimming pool must be grounded with a
solid copper conductor that's no smaller than
A. AWG 8.
B. AWG 12.
C. AWG 10.
D. AWG 6.