A 75 HP, 3-phase, synchronous motor is connected to a 230-volt line. The motor is to be operated at 80% power factor. The motor nameplate lists a full load current of 185 amperes, a temperature rise of 40°C, and a code letter A. The conductors are to be made of copper and have type THHN insulation. The short-circuit protective device is to be an inverse time circuit breaker. Determine the conductor size, overload heater size, circuit breaker size, and the minimum size NEMA and IEC starters. The starter contains current transformers with a ratio of 300:5 to reduce current to the overload heater O Conductor size 250KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA5)(IEC R or S) Conductor size 250KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA6)(IEC R or S) Conductor size 350KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA5)(IEC R or S) Conductor size 300KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA5)(IEC R or S)
A 75 HP, 3-phase, synchronous motor is connected to a 230-volt line. The motor is to be operated at 80% power factor. The motor nameplate lists a full load current of 185 amperes, a temperature rise of 40°C, and a code letter A. The conductors are to be made of copper and have type THHN insulation. The short-circuit protective device is to be an inverse time circuit breaker. Determine the conductor size, overload heater size, circuit breaker size, and the minimum size NEMA and IEC starters. The starter contains current transformers with a ratio of 300:5 to reduce current to the overload heater O Conductor size 250KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA5)(IEC R or S) Conductor size 250KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA6)(IEC R or S) Conductor size 350KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA5)(IEC R or S) Conductor size 300KCMIL, Overload size X42 Inverse time circuit breaker 500A Starter size(NEMA5)(IEC R or S)
Chapter14: Phase Failure Relays
Section: Chapter Questions
Problem 1SQ: What is the purpose of phase failure relays?
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 5 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you