11. Four big tanks in a chemistry industry contains different liquids being heated. There are liquids level sensors in order to detect always when the level in the tank A ou B goes above a certain level. The temperature sensors in the tanks C and D detect when the temperature of one of them goes below determined limit. Suppose that the outputs A and B will be LOW, with the satisfactory level and it will be HIGH, when the level goes too high. Also, the outputs C and D of the temperature sensors will be LOw, with the satisfactory temperature, and it will HIGH, when it gets too low. Project a simplified logic circuit that detects always that a level in the tank A or B gets high, at the same time that the temperature in one of the tanks C or D gets too low.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter30: Dc Motors
Section: Chapter Questions
Problem 6RQ: What is CEMF?
icon
Related questions
Question
100%

Can anyone help? Use Karnaugh Map for this one

11. Four big tanks in a chemistry industry contains different liquids
being heated. There are liquids level sensors in order to detect
always when the level in the tank A ou B goes above a certain level.
The temperature sensors in the tanks C and D detect when the
temperature of one of them goes below determined limit.
Suppose that the outputs A and B will be LOW, with the satisfactory
level and it will be HIGH, when the level goes too high. Also, the
outputs C and D of the temperature sensors will be LOw, with the
satisfactory temperature, and it will HIGH, when it gets too low.
Project a simplified logic circuit that detects always that a level in
the tank A or B gets high, at the same time that the temperature in
one of the tanks C or D gets too low.
Transcribed Image Text:11. Four big tanks in a chemistry industry contains different liquids being heated. There are liquids level sensors in order to detect always when the level in the tank A ou B goes above a certain level. The temperature sensors in the tanks C and D detect when the temperature of one of them goes below determined limit. Suppose that the outputs A and B will be LOW, with the satisfactory level and it will be HIGH, when the level goes too high. Also, the outputs C and D of the temperature sensors will be LOw, with the satisfactory temperature, and it will HIGH, when it gets too low. Project a simplified logic circuit that detects always that a level in the tank A or B gets high, at the same time that the temperature in one of the tanks C or D gets too low.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning