10,000 kg/hr of an aqueous feed containing 1% dissolved solids is to be concentrated to 20% solids, in a single effect evaporator. The feed enters at 25°C. The steam chest is fed with saturated steam at 110°C. The absolute pressure maintained in the evaporator is such that the water will boil at 55°C. The heat transfer area available is 50 m2. The boiling point cievations are as follows: Feed: 0.2°C; 20% solution: 15°C 'The overall heat transfer coefficient, under normal operating conditions would be 2500 W/m2.°C. Estimate the heat load on the condenser, assuming no sub cooling of condensate.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
100%
10,000 kg/hr of an aqueous feed containing 1% dissolved solids is to be concentrated to 20%
solids, in a single effect evaporator. The feed enters at 25°C. The steam chest is fed with
saturated steam at 110°C. The absolute pressure maintained in the evaporator is such that
the water will boil at 55°C. The heat transfer area available is 50 m2. The boiling point
cievations are as follows:
Feed: 0.2° C; 20% solution: 15°C
The overall heat transfer coefficient, under normal operating conditions would be 2500
W/m2.°C. Estimate the heat load on the condenser, assuming no sub cooling of condensate.
Transcribed Image Text:10,000 kg/hr of an aqueous feed containing 1% dissolved solids is to be concentrated to 20% solids, in a single effect evaporator. The feed enters at 25°C. The steam chest is fed with saturated steam at 110°C. The absolute pressure maintained in the evaporator is such that the water will boil at 55°C. The heat transfer area available is 50 m2. The boiling point cievations are as follows: Feed: 0.2° C; 20% solution: 15°C The overall heat transfer coefficient, under normal operating conditions would be 2500 W/m2.°C. Estimate the heat load on the condenser, assuming no sub cooling of condensate.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The