10. changing the output signal of the speech-processor circuit of a cochlear prosthesis will not affect the stimulus controller. True False 11 In Onkil

Human Anatomy & Physiology (11th Edition)
11th Edition
ISBN:9780134580999
Author:Elaine N. Marieb, Katja N. Hoehn
Publisher:Elaine N. Marieb, Katja N. Hoehn
Chapter1: The Human Body: An Orientation
Section: Chapter Questions
Problem 1RQ: The correct sequence of levels forming the structural hierarchy is A. (a) organ, organ system,...
icon
Related questions
Question

10. changing the output signal of the speech-processor circuit of a cochlear
prosthesis will not affect the stimulus controller.
True
False.
11. In Ophthalmic laser, the laser enerov muuet be fixed for different spot sizes.
Truew
False.
12. In hemodialysis machine the bypass valve will be activated in case of .* ***
A: wrong composition of the dialysis fluid.
C: the temperature of the dialysate.
B. traces of blood are detected.
D. All,
13. Depending on the hardness of the local water. Calcium and magnesium are
usually removed from the water by using a water softener or a de-ionizer.
True
False.
14. A rotameter and needle valve flow controller are used to regulate the Oxygen
flow to the oxygenator.
True
False.
15. Ventricular sensing is required for temporary AV conduction failure that must be
detected in order to apply ventricular stimulation.
True
False.
16. In anesthesia machine, the monitoring subsystem is used for
A. patient supervision. B. equipment supervision.
C both A and B.
17. In case of volume-controlled ventilation, the therapist sets the parameters of the
airway pressure controller.
True,
False.
18. compared to air-driven dental handpiece, the micromotor provides precise
cutting with lower vibration.
True
False.
19. The concentration of the anesthetic agent flowing out of the variable bypass
vaporizer is directly related to ...
A concentration cone.
B. bypass channel.
C. Temperature -compensation bellows
20. The intensity of the operating light used in dental chair is (40k-160k) lux.
True
False.
2 3
Transcribed Image Text:10. changing the output signal of the speech-processor circuit of a cochlear prosthesis will not affect the stimulus controller. True False. 11. In Ophthalmic laser, the laser enerov muuet be fixed for different spot sizes. Truew False. 12. In hemodialysis machine the bypass valve will be activated in case of .* *** A: wrong composition of the dialysis fluid. C: the temperature of the dialysate. B. traces of blood are detected. D. All, 13. Depending on the hardness of the local water. Calcium and magnesium are usually removed from the water by using a water softener or a de-ionizer. True False. 14. A rotameter and needle valve flow controller are used to regulate the Oxygen flow to the oxygenator. True False. 15. Ventricular sensing is required for temporary AV conduction failure that must be detected in order to apply ventricular stimulation. True False. 16. In anesthesia machine, the monitoring subsystem is used for A. patient supervision. B. equipment supervision. C both A and B. 17. In case of volume-controlled ventilation, the therapist sets the parameters of the airway pressure controller. True, False. 18. compared to air-driven dental handpiece, the micromotor provides precise cutting with lower vibration. True False. 19. The concentration of the anesthetic agent flowing out of the variable bypass vaporizer is directly related to ... A concentration cone. B. bypass channel. C. Temperature -compensation bellows 20. The intensity of the operating light used in dental chair is (40k-160k) lux. True False. 2 3
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Visual perception
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, biology and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Human Anatomy & Physiology (11th Edition)
Human Anatomy & Physiology (11th Edition)
Biology
ISBN:
9780134580999
Author:
Elaine N. Marieb, Katja N. Hoehn
Publisher:
PEARSON
Biology 2e
Biology 2e
Biology
ISBN:
9781947172517
Author:
Matthew Douglas, Jung Choi, Mary Ann Clark
Publisher:
OpenStax
Anatomy & Physiology
Anatomy & Physiology
Biology
ISBN:
9781259398629
Author:
McKinley, Michael P., O'loughlin, Valerie Dean, Bidle, Theresa Stouter
Publisher:
Mcgraw Hill Education,
Molecular Biology of the Cell (Sixth Edition)
Molecular Biology of the Cell (Sixth Edition)
Biology
ISBN:
9780815344322
Author:
Bruce Alberts, Alexander D. Johnson, Julian Lewis, David Morgan, Martin Raff, Keith Roberts, Peter Walter
Publisher:
W. W. Norton & Company
Laboratory Manual For Human Anatomy & Physiology
Laboratory Manual For Human Anatomy & Physiology
Biology
ISBN:
9781260159363
Author:
Martin, Terry R., Prentice-craver, Cynthia
Publisher:
McGraw-Hill Publishing Co.
Inquiry Into Life (16th Edition)
Inquiry Into Life (16th Edition)
Biology
ISBN:
9781260231700
Author:
Sylvia S. Mader, Michael Windelspecht
Publisher:
McGraw Hill Education