(10 kVA, 200/20 V, 50 Hz values are written on the plate of a 1 phase transformer. The values given at Table 1 was measured the open circuit test for this transformer. Draw the "referred to low voltage side" approximate (L type) electrical equivalent circuit of the transformer by writing all the values (which can be found with the measured parameters at the applied test) of circuit elements onto the figure.) Tablol (Table 1). Açık devre test ölçümleri (Open circuit test measurements) Açık devre testi-yüksek gerilim tarafı açık devre (Open circuit test-high volt. side is open circuit) 200 V V A W 2,7 A 120 W

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Electromechanical energy conversion
(10 kVA, 200/20 V, 50 Hz values are written on the plate of a 1 phase transformer. The values
given at Table 1 was measured at the open circuit test for this transformer. Draw the "referred to
low voltage side" approximate (L type) electrical equivalent circuit of the transformer by
writing all the values (which can be found with the measured parameters at the applied test) of
circuit elements onto the figure.)
Tablol (Tablel). Açık devre test ölçümleri (Open circuit test measurements)
Açık devre testi-yüksek gerilim tarafı açık devre (Open circuit test-high volt. side is open circuit)
200 V
2,7 A
120 W
V
A
W
Transcribed Image Text:(10 kVA, 200/20 V, 50 Hz values are written on the plate of a 1 phase transformer. The values given at Table 1 was measured at the open circuit test for this transformer. Draw the "referred to low voltage side" approximate (L type) electrical equivalent circuit of the transformer by writing all the values (which can be found with the measured parameters at the applied test) of circuit elements onto the figure.) Tablol (Tablel). Açık devre test ölçümleri (Open circuit test measurements) Açık devre testi-yüksek gerilim tarafı açık devre (Open circuit test-high volt. side is open circuit) 200 V 2,7 A 120 W V A W
Expert Solution
steps

Step by step

Solved in 4 steps with 5 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,