1. You have been hired by a homeowner to install a ceiling fan and light kit in a living room. The living room luminaire (light fixture) being used at present contains two 60-W lamps. After locating the circuit in the panel box, you find that the circuit is protected by a 15-A circuit breaker and is run with 14 AWG copper wire. After turning on all lights connected to this circuit, you have a current draw of 8.6 A and a voltage of 120 V. The ceiling fan light kit contains four 60-W lamps, and the fan has a maximum current draw of 1.6 A. Can this fan be connected to the existing living room circuit? Recall that a continuous-use circuit should not be loaded to more than 80% of its rated capacity.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Pratical application 1.)

**Practical Applications**

1. **Ceiling Fan and Light Installation**

   You have been hired by a homeowner to install a ceiling fan and light kit in a living room. The existing living room luminaire (light fixture) contains two 60-W lamps. Upon checking the circuit in the panel box, you discover that it is protected by a 15-A circuit breaker and uses 14 AWG copper wire. With all lights turned on, the circuit exhibits a current draw of 8.6 A at a voltage of 120 V. The new ceiling fan light kit includes four 60-W lamps, and the fan alone has a maximum current draw of 1.6 A. Determine whether this fan can be connected to the existing living room circuit, noting that a continuous-use circuit should not exceed 80% of its rated capacity.

2. **Industrial Plant Heating System**

   You are employed in a large industrial plant where a 480-V, 5000-W heater is used to melt lead in a large tank. It has been observed that the heater alone is insufficient to raise the temperature to the desired level. A second 5000-W heater is to be installed in the tank. Evaluate whether the electrical system can support this additional load after installation.
Transcribed Image Text:**Practical Applications** 1. **Ceiling Fan and Light Installation** You have been hired by a homeowner to install a ceiling fan and light kit in a living room. The existing living room luminaire (light fixture) contains two 60-W lamps. Upon checking the circuit in the panel box, you discover that it is protected by a 15-A circuit breaker and uses 14 AWG copper wire. With all lights turned on, the circuit exhibits a current draw of 8.6 A at a voltage of 120 V. The new ceiling fan light kit includes four 60-W lamps, and the fan alone has a maximum current draw of 1.6 A. Determine whether this fan can be connected to the existing living room circuit, noting that a continuous-use circuit should not exceed 80% of its rated capacity. 2. **Industrial Plant Heating System** You are employed in a large industrial plant where a 480-V, 5000-W heater is used to melt lead in a large tank. It has been observed that the heater alone is insufficient to raise the temperature to the desired level. A second 5000-W heater is to be installed in the tank. Evaluate whether the electrical system can support this additional load after installation.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Economic load dispatch
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,