1. You have been hired by a homeowner to install a ceiling fan and light kit in a living room. The living room luminaire (light fixture) being used at present contains two 60-W lamps. After locating the circuit in the panel box, you find that the circuit is protected by a 15-A circuit breaker and is run with 14 AWG copper wire. After turning on all lights connected to this circuit, you have a current draw of 8.6 A and a voltage of 120 V. The ceiling fan light kit contains four 60-W lamps, and the fan has a maximum current draw of 1.6 A. Can this fan be connected to the existing living room circuit? Recall that a continuous-use circuit should not be loaded to more than 80% of its rated capacity.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Pratical application 1.)

**Practical Applications**

1. **Ceiling Fan and Light Installation**

   You have been hired by a homeowner to install a ceiling fan and light kit in a living room. The existing living room luminaire (light fixture) contains two 60-W lamps. Upon checking the circuit in the panel box, you discover that it is protected by a 15-A circuit breaker and uses 14 AWG copper wire. With all lights turned on, the circuit exhibits a current draw of 8.6 A at a voltage of 120 V. The new ceiling fan light kit includes four 60-W lamps, and the fan alone has a maximum current draw of 1.6 A. Determine whether this fan can be connected to the existing living room circuit, noting that a continuous-use circuit should not exceed 80% of its rated capacity.

2. **Industrial Plant Heating System**

   You are employed in a large industrial plant where a 480-V, 5000-W heater is used to melt lead in a large tank. It has been observed that the heater alone is insufficient to raise the temperature to the desired level. A second 5000-W heater is to be installed in the tank. Evaluate whether the electrical system can support this additional load after installation.
Transcribed Image Text:**Practical Applications** 1. **Ceiling Fan and Light Installation** You have been hired by a homeowner to install a ceiling fan and light kit in a living room. The existing living room luminaire (light fixture) contains two 60-W lamps. Upon checking the circuit in the panel box, you discover that it is protected by a 15-A circuit breaker and uses 14 AWG copper wire. With all lights turned on, the circuit exhibits a current draw of 8.6 A at a voltage of 120 V. The new ceiling fan light kit includes four 60-W lamps, and the fan alone has a maximum current draw of 1.6 A. Determine whether this fan can be connected to the existing living room circuit, noting that a continuous-use circuit should not exceed 80% of its rated capacity. 2. **Industrial Plant Heating System** You are employed in a large industrial plant where a 480-V, 5000-W heater is used to melt lead in a large tank. It has been observed that the heater alone is insufficient to raise the temperature to the desired level. A second 5000-W heater is to be installed in the tank. Evaluate whether the electrical system can support this additional load after installation.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Economic load dispatch
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,