1. The Open Circuit Curve of a 2000 V,900KVA Synchronous Generator is given below. Line voltage(volt) 500 1000 1500 2000 2400 2760 3080 3360 Field current(amp) 1 3 4 5 6 7 8 The armature resistance is 0.1 ohm and its synchronous reactance is 1.3 ohm.The friction and windage losses are 16 kW and core losses are 13 kW.The generator is Y connected.Frequency is 60 Hz.Number of poles is 4. The 3-phase lond is connected as Y. (a)Assume that the generator operates at 80% of the rated load.The load voltage is the rated voltage.Calculate the internal voltage at 0.85 pf leading load.What will be the corresponding field current? (b)Calculate the Voltage Regulation.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
1. The Open Circuit Curve of a 2000 V,900KVA Synchronous Generator is given below.
Line voltage(volt)
500 1000 1500 2000 2400 2760 3080 3360
Field current(amp)
1
2
3
4
5
6
7
8
The armature resistance is 0.1 ohm and its synchronous reactance is 1.3 ohm.The friction and
windage losses are 16 kW and core losses are 13 kW.The generator is Y connected.Frequency is 60
Hz.Number of poles is 4. The 3-phase lond is connected as Y.
(a)Assume that the generator operates at 80% of the rated load.The load voltage is the rated
voltage.Calculate the internal voltage at 0.85 pf leading load.What will be the corresponding field
current?
(b)Calculate the Voltage Regulation.
(c)Calculate the efficiency of the generator.Calculate the input torque.
jl.32
O.L
Meel=2000v
EB
jl.32
ji.32
Transcribed Image Text:1. The Open Circuit Curve of a 2000 V,900KVA Synchronous Generator is given below. Line voltage(volt) 500 1000 1500 2000 2400 2760 3080 3360 Field current(amp) 1 2 3 4 5 6 7 8 The armature resistance is 0.1 ohm and its synchronous reactance is 1.3 ohm.The friction and windage losses are 16 kW and core losses are 13 kW.The generator is Y connected.Frequency is 60 Hz.Number of poles is 4. The 3-phase lond is connected as Y. (a)Assume that the generator operates at 80% of the rated load.The load voltage is the rated voltage.Calculate the internal voltage at 0.85 pf leading load.What will be the corresponding field current? (b)Calculate the Voltage Regulation. (c)Calculate the efficiency of the generator.Calculate the input torque. jl.32 O.L Meel=2000v EB jl.32 ji.32
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Economic load dispatch
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,