1. Aring core current transformer of ration 1000/5 A is operating at full primary current with the secondary burden of non-inductive resistance of 1.1 2. It's exciting current is JA at a power factor of 0.45. Calculate: the ratio error at full load, assuming that there apensation and the phase angle.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Answer question three
Question 1
1. The coil of a PMMC voltmeter is 40 mm Jong and 20 mm wide and has 120 turns on t
The control spring exerts a torque of 90- 10-6 N - m when the deflection in 100
divisions on full scale deflection. If the flux density of the magnetic field in the air gap is
0.4 Wb/m', determine the resistance required to be connected in series with the coil to
give one volt per division. Assume the resistance of the coil to be 1.5 kfl.
2. Two lamps LI =50 2 and L2= 100 2 are connected in series with a 110V DC source
Find the error in the measure power in L1 using voltmeter -ammeter method and in ideal
real conditions, given that the internal resistance of voltmeter is 120 k2 and that of the
ammeter is 0.2 m2, when (a) voltmeter is connected near L2 than the ammeter and (b)
the ammeter is connected near L2 than the voltmeter.
3. With the aid of illustrations and suitable expressions, explain how ammeters and
voltmeter can have their range extended.
Question 2
1. A set of physical length measurements were taken and results are as follows: 1.45, 1.44,
1.57,1.48, 1.43, 1:46,1.54,1.49,1.41,1.60 m. Assuming that only random errors are
present, Calculate Arithmetic mean, average deviation, standard deviation and variance.
2. In a balanced 3 phase circuit power is measured by two wattmeter method. If the ratio of
the two meter readings is 3:1.5, determine the power factor of the connected load.
3. Explain the main difference among indicating, recording, integrated and null detector
instruments
Question 3
1. A ring core current transformer of ration 1000/5 A is operating at full primary current
with the secondary burden of non-inductive resistance of 1.1 2. It's exciting current is
1A at a power factor of 0.45. Caleulate: the ratio error at full load, assuming that there
has been no compensation, and the phase angle.
2. A load takes a current of 2.6 A, a non-inductive resistor connected in parallel take 2.4A
when connected across a22 V supply. If the total current take from the supply is 4.6 in the
three wattmeter method of single-phase AC power measurement circuit, calculate the
power consumed by the load, load impedance and load power factor.
3. With an illustration explain the operation of PLCS and state their main advantages over
hard wired relays.
Transcribed Image Text:Question 1 1. The coil of a PMMC voltmeter is 40 mm Jong and 20 mm wide and has 120 turns on t The control spring exerts a torque of 90- 10-6 N - m when the deflection in 100 divisions on full scale deflection. If the flux density of the magnetic field in the air gap is 0.4 Wb/m', determine the resistance required to be connected in series with the coil to give one volt per division. Assume the resistance of the coil to be 1.5 kfl. 2. Two lamps LI =50 2 and L2= 100 2 are connected in series with a 110V DC source Find the error in the measure power in L1 using voltmeter -ammeter method and in ideal real conditions, given that the internal resistance of voltmeter is 120 k2 and that of the ammeter is 0.2 m2, when (a) voltmeter is connected near L2 than the ammeter and (b) the ammeter is connected near L2 than the voltmeter. 3. With the aid of illustrations and suitable expressions, explain how ammeters and voltmeter can have their range extended. Question 2 1. A set of physical length measurements were taken and results are as follows: 1.45, 1.44, 1.57,1.48, 1.43, 1:46,1.54,1.49,1.41,1.60 m. Assuming that only random errors are present, Calculate Arithmetic mean, average deviation, standard deviation and variance. 2. In a balanced 3 phase circuit power is measured by two wattmeter method. If the ratio of the two meter readings is 3:1.5, determine the power factor of the connected load. 3. Explain the main difference among indicating, recording, integrated and null detector instruments Question 3 1. A ring core current transformer of ration 1000/5 A is operating at full primary current with the secondary burden of non-inductive resistance of 1.1 2. It's exciting current is 1A at a power factor of 0.45. Caleulate: the ratio error at full load, assuming that there has been no compensation, and the phase angle. 2. A load takes a current of 2.6 A, a non-inductive resistor connected in parallel take 2.4A when connected across a22 V supply. If the total current take from the supply is 4.6 in the three wattmeter method of single-phase AC power measurement circuit, calculate the power consumed by the load, load impedance and load power factor. 3. With an illustration explain the operation of PLCS and state their main advantages over hard wired relays.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,