1. A. Using the Steam Tables, determine the amount of cooling water needed by a condenser in kg/sec if wet steam comes into the condenser at P= 610.44mmHG vac and 99.47 % moisture , mass flow rate = 7200 + (X/SN) kg/hr. Cooling water enters the condenser at 12 B. Draw the schematic diagram of the condenser and process in the PV and TS TA deg C and leaves at 21 deg C. Answer: diagrams below. Cp H2O = 4.187 KJ/(kg-K): Schematic diagram of heat exchanger =condenser

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter40: Typical Operating Conditions
Section: Chapter Questions
Problem 2RQ: The typical temperature relationship between a standard-efficiency air-cooled condenser and the...
icon
Related questions
icon
Concept explainers
Question

SN = 9 
X = 20 

1. A. Using the Steam Tables, determine the amount of cooling water needed by a condenser in kg/sec if wet steam comes into the
condenser at P= 610.44mmHG vac and 99.47 % moisture , mass flow rate = 7200 + (X/SN) kg/hr. Cooling water enters the condenser at 12
deg C and leaves at 21 deg C. Answer:
diagrams below. Cp H2O = 4.187 KJ/(kg-K):
B. Draw the schematic diagram of the condenser and process in the PV and TS
Schematic diagram
of heat exchanger
=condenser
Transcribed Image Text:1. A. Using the Steam Tables, determine the amount of cooling water needed by a condenser in kg/sec if wet steam comes into the condenser at P= 610.44mmHG vac and 99.47 % moisture , mass flow rate = 7200 + (X/SN) kg/hr. Cooling water enters the condenser at 12 deg C and leaves at 21 deg C. Answer: diagrams below. Cp H2O = 4.187 KJ/(kg-K): B. Draw the schematic diagram of the condenser and process in the PV and TS Schematic diagram of heat exchanger =condenser
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Design Against Fluctuating Loads
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning