03. (a) O Discuss the constant VHz control method of electric motors with the support of a diagram. (i) A 1100-kVA. 460V. 60HZ. three-phase. four-pole synchronous motor is to be driven from a variable frequency. three-phase constant VHz inverter rated at 125KVA. The synchronous motor has a synchronous reactance of 1.18 per unit and achieves rated pen-circuit voltage at a field current of 8.SA. Determine the field current required to achieve unity power factor operation if the motor operates at rated voltage and speed with an input power of IMW.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
Q3.
(a)
(i) Discuss the constant V/Hz control method of electric motors with the
support of a diagram.
(ii) A 1100-kVA, 460V, 60HZ, three-phase, four-pole synchronous
motor is to be driven from a variable frequency, three-phase
constant V/Hz inverter rated at 125KVA. The synchronous motor has a
synchronous reactance of 1.18 per unit and achieves rated pen-circuit
voltage at a field current of 8.5A. Determine the field current required
to achieve unity power factor operation if the motor operates at rated
voltage and speed with an input power of 1MW.
Transcribed Image Text:Q3. (a) (i) Discuss the constant V/Hz control method of electric motors with the support of a diagram. (ii) A 1100-kVA, 460V, 60HZ, three-phase, four-pole synchronous motor is to be driven from a variable frequency, three-phase constant V/Hz inverter rated at 125KVA. The synchronous motor has a synchronous reactance of 1.18 per unit and achieves rated pen-circuit voltage at a field current of 8.5A. Determine the field current required to achieve unity power factor operation if the motor operates at rated voltage and speed with an input power of 1MW.
Expert Solution
steps

Step by step

Solved in 6 steps with 4 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,