".I need the correct answers with explanations" Q1: What is the orientation of voltage regulation value (positive or negative) of alternator loaded by capacitive load? Explain the effect of armature reaction on voltage regulation for this load? Draw the load characteristics of alternator for capacitive, inductive, and inductive loads? Q2: A 2000 kVA,2200 V, 60 Hz,Y-connected alternator has a resistance of 0.25 between each pair of terminal. A field current of 80 A produces a short circuit current equal to full load current in each line. The same field current produces an e.m.f of 800 V(L-L) on open circuit .Determine the full load voltage regulation of alternator at unity p.f?

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter31: Three-phase Alternators
Section: Chapter Questions
Problem 1RQ: What conditions must be met before two alternators can be paralleled together?
icon
Related questions
Question
".I need the correct answers with explanations"
Q1: What is the orientation of voltage regulation value (positive or negative) of
alternator loaded by capacitive load? Explain the effect of armature reaction on
voltage regulation for this load? Draw the load characteristics of alternator for
capacitive, inductive, and inductive loads?
Q2: A 2000 kVA,2200 V, 60 Hz,Y-connected alternator has a resistance of 0.25
between each pair of terminal. A field current of 80 A produces a short circuit current equal to full load
current in each line. The same field current produces an e.m.f of 800 V(L-L) on open circuit .Determine the full
load voltage regulation of alternator at unity p.f?
Transcribed Image Text:".I need the correct answers with explanations" Q1: What is the orientation of voltage regulation value (positive or negative) of alternator loaded by capacitive load? Explain the effect of armature reaction on voltage regulation for this load? Draw the load characteristics of alternator for capacitive, inductive, and inductive loads? Q2: A 2000 kVA,2200 V, 60 Hz,Y-connected alternator has a resistance of 0.25 between each pair of terminal. A field current of 80 A produces a short circuit current equal to full load current in each line. The same field current produces an e.m.f of 800 V(L-L) on open circuit .Determine the full load voltage regulation of alternator at unity p.f?
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning