MIST WK 1- Video Case 1. Why does Facebook’s data center specialist argue that “The Internet is not a cloud?” Facebooks’ data center specialists argue that “The internet is not a cloud” because many people believe their information is in a cloud and just floating around but in reality it is not. It is a real physical thing that it is stored in a building that is interconnected through miles and miles of cable and fiber. These buildings are all interconnected and can talk to each other and share data with each other back and forth. These buildings are all supplied with enough power to where they should never crash but just in case they do run into a power failure they have massive diesel run generators that can be used as a backup. 2. What are some of the techniques Facebook uses to cool its data centers? One of the techniques that Facebook uses to cool down its data center is by using a massive 7 room rooftop that is a natural air conditioning system. It takes the cool air from outside and sucks it in and then is mixed with warm air to regulate the temperature. There is then a mist that sprays out to control the humidity and the chilled air sinks to the back of each server stopping them from overheating. Then all of the excess warm air is pushed out in massive fans. For reference on how big these fans are they are 100 times the size of the fans that are in a laptop. 3. Describe the five methods recommended by Google for reducing power consumption. The first method recommended by google is Measure PUW (power usage effectiveness). PUE is the ratio of total facility energy/IT equipment energy within the data center. It measures how effectively power and cooling is delivered to the IT equipment. In the best case scenario you want the PUE to get to as close to 1.0 as possible. You should measure PUE as often as possible and even every second if possible. To make this easier Google incorporates PUE into their building management system. The second method is Manage Airflow where they want to eliminate the mixing of the hot and the cold air. One useful way to find this is CFD(Computational Fluid Dynamics) analysis which shows you where your hot spots are and your air flow is directed in your data center. You can use thermal modeling to find the hot spots which helps them find solutions in how to create more air flow. The next method is Adjust thermostat Google found that by raising their thermostat from 72 degrees to 80 degrees saved them thousands of dollars in energy costs each year. The fourth method is Utilize Free Cooling
which is when you use the cooling from outside of your data center to provide cooling without operating equipment like chillers. Some sites use evaporative cooling in an efficient fashion which saves water. The fifth method is to optimize power distribution by minimizing the conversion stages in the data center. You can save energy and money. 4. Based on the Google video, how much of the world’s global greenhouse gasses are the result of computing? According to the video 2 percent of the world's global greenhouse gasses are the result of computing. Of this 2 percent of greenhouse gasses the data center is responsible for about 15 percent. There are many different ways to make energy more efficient and help bring down this statistic. In the video it goes on to explain all of Google's practices that they use to be a more efficient company and become better for the environment. There are five methods that they give to reduce the power consumption and become more efficient. They are making these suggestions to companies and people to try and help to spread the word of bringing down greenhouse gasses and making this world a cleaner and more energy efficient place. 5. What are some of the benefits of using Dell’s Triton water cooling technology? One benefit of Dell’s Triton water cooling technology is higher computer performance. This means that computers can run better and more efficiently while also keeping up with the bigger workloads that come along with it. This makes for quicker and better performance and these computers can take on a lot more tasks and information because they are made to accommodate the larger workloads that people need. The cpu is able to be pushed to another level of performance, it translates the additional power and cooling headroom and to higher frequency on the cpu which yields the higher performance which helps put through workloads for every customer.
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help