Lab 4: Operational Amplifiers Part 2 Rufus Tadpatri ECEN 325-504
Measurement Plots Summing Amplifier Time Domain Waveforms: Clipping occurs:
Differential Amplifier Time Domain Waveforms: ADM:
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
ACM: Instrumental Amplifier Time Domain Waveforms:
Table Summing Input Voltgage 106 mV Output Voltage -484 mV Vi2 where clipping occurs 1.81 V Differential Input Voltgage 112 mV Output Voltage 126 mV ADM = Vo/Vi 114 mV/108 mV = 1.05555555555 ACM = Vo/Vi 25 mV/108 mV = 0.231 CMMR ADM/ACM = 4.57 20log(4.57) = 13.198 Instrumentation Input Voltgage 109 mV Output Voltage 1.234 V Comparison The results and values are mostly the same with very little discrepancy. The simulations take on the same shape and the values vary only slightly. For simulating the CMMR, I was unable to simulate a graph with conclusive results. Additionally, for the summing amplifier, my measured result was the opposite of the simulated result. This could be a product of an error in wiring the circuit or in designing the circuit on multisim.