Question
Chapter 9, Problem 9.8P
To determine
Find the factor of safety against heaving at point A.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
2. A site is underlain by a 5m-thick layer of clay. Below the layer of clay lies a 7m-thick layer of sand. The water table is
located 2m below the ground surface. Draw the profile. Then, calculate the vertical effective stress at a point located 6m
below the ground surface. Show your work and circle the answer.
***The answer includes:
1. The correct dimension of variables is: F: MLT^-2, v: LT^-1, μ:ML^-1T^-1, ρ: ML^-3, w: L
2. Choice of repeating variables: (w,v,ρ). Choice does NOT include F. Stick with choice throughout.
3. # pi terms = # variables- # dimensions = 5-3=2.
4. π1= F/w^2v^2ρ
5. π2= μ/wvp
These are the correct answers for the problem, I just need the work involved in solving it
The cross-section shown is used to support the loads on
the beam below. The moment of inertia of the section is |=
1384 in4 and distance of the centroid of the section from
the bottom is y = 5.8 in.
[MA=4800 lb-ft, w=600 lb/ft, P=1400 lb, a=5ft,b=7ft,c=
2 ft,d=5ft]
Ma
b
ཅ་
d
15 in
1.5 in
1.5 in.
2 in.
k11 in.
Cross section of the beam
a) Construct the complete shear-force and
bending-moment diagrams for the beam and
determine the maximum positive bending
moment in the beam.
b) determine the maximum negative bending
moment in the beam.
c) Determine the maximum tension bending
stress at any location along the beam.
d) Determine the maximum compression
bending stress at any location along the beam.
Chapter 9 Solutions
Bundle: Principles Of Geotechnical Engineering, Loose-leaf Version, 9th + Mindtap Engineering, 2 Terms (12 Months) Printed Access Card
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- COMPUTE THE VOLUME OF THE STOCKPILE SHOWN BELOW IN CUBIC YARDS USING THE AVERAGE AREA METHOD. PROVIDE YOUR RESULTS ON THIS PAGE USING THE WINDOWS CLIPBOARD CUT AND PASTE TOOLS. 166 170 168 -172 CONTOUR AREA = 2,663 S.F. CONTOUR AREA = 8,217 S.F CONTOUR AREA = 16,284 S.F CONTOUR AREA = 29,734 S.F. AVERAGE AREA METHOD FOR VOLUME OF EXCAVATION AND STOCKPILE CONTOUR ELEVATION CONTOUR AREA (FT) (FT³) ELEVATION DIFFERENCE (DEPTH) BETWEEN CONSECUTIVE CONTOURS AVERAGE AREA BETWEEM CONSECUTIVE CUMMULATIVE CONTOURS VOLUME (FT³) CUMMULATIVE VOLUME VOLUME (CY) (FT³) (FT) (FT)arrow_forwardUsing the graphic below, computer the bearings for courses AF, AB, and BC and azimuths for courses AF and BC. 128°28'58" 0.00 TRV-A 65°5'34" F 86°34'27" B 0.00 TRY-B • Azimuth AF: Bearing AF: Bearing AB: Azimuth BC: Bearing BC:arrow_forward4G 46:58 Problem 1 You are in the process of designing a water supply system for the whole Iligan City, and the design life of your system is to end in the year 2070. The population in the town has been measured every 10 years since 1980 by the Philippine Statistics Authority, and the reported populations are tabulated below. Estimate the population in the town using (a) arithmetic growth projection, (b) geometric growth projection (exponential formula), (c) declining growth projection (assuming a saturation concentration of 480,000 people), and (d) logistic curve projection. Population Year 1980 167,358 1990 226,568 2000 285,061 2010 322,821 2020 342,618 1.a) Arithmetic growth projection estimate Your answer * 5 points 1.b) Geometric growth * 5 points projection estimate Your answer 1.c) Declining growth projection estimate Your answer * 10 points כ 95arrow_forward
- 2. Design a W section for a beam of A 36 steel Fy = 248 MPa to carry a uniform load of 293 kN/m on a simply supported span of 1.5 m. Assume lateral bracing is adequate for stability. Wt. of beam Area Depth (d) Properties of W sections available W 12 x 27 394.9 N/m Flange width (bf) Flange thickness (tf) Web thickness (tw) Moment of inertia (IX) Section modulus (SX) 5129 303.78 165.02 10.16 6.02 84.9 x 106 mm² 560.4 x 103 mm³ 3 W 12 x 31 453.4 N/m 5890 W 14 x 26 380.27 N/m 4948 307.09 352.81 165.74 127.64 11.81 10.62 6.73 6.48 99.5 x 106 mm² 101.56 x 106 mm4 674.3 x 103 mm³ 575.2 x 103 mm³arrow_forward⚫ For the semi-circular arch shown in Fig.2, draw shear and bending moment diagram. 10 kN 5 m SkNarrow_forwardQ2: A 2 m X 3 m foundation is expected to carry a column load with eccentricities eB = 0.15 m and eL = 0.2 m. It is placed in a soil where e' = 10.0 kN/m2, 0'= 22°, and y = 18.0 kN/m², at 1.0 m depth. Determine the maximum load the foundation can carry with factor of safety of 3.arrow_forward
- Determine the forces in each member for the truss shown in using joint method and state if the member is in tension or compression. Wake table to show your final results. 24 kN 4 m 4 m 4 m SkN 3m shear Narrow_forwardI need help calculating my VPC 0f 14+50, VPI 17+00 and VPT 19+50 elevations if I am given Sta 11+00 with elevation 5946.31. Problem 32 in the image below gives g1 and g2, k=64.arrow_forwardused to support the loads on the beam below. The moment of inertia of the section is |= 1384 in and distance of the centroid of the section from the bottom is y = 5.8 in. [MA 4000 lb-ft, w=900 lb/ft, P=1500 lb, a = 5 ft, b = 8 ft, c = 3 ft, d = 6 ft] Ma W a b B d P 1.5 in.k 1.5 in. 15 in. z- 2 in. 11 in. Cross section of the beam Construct the complete shear- force and bending-moment diagrams for the beam and determine the maximum positive bending moment in the beam.arrow_forward
- The cross-section shown is used to support the loads on the beam below. The moment of inertia of the section is |= 1384 in and distance of the centroid of the section from the bottom is y = 5.8 in. [MA-4000 lb-ft, w=900 lb/ft, P=1500 lb, a = 5 ft, b = 8 ft, c = 3 ft, d = 6 ft] Ma 15 in 1.5 in 13 in. 2 in 11 in. Cross section of the beam Determine the maximum tension bending stress at any location along the beam.arrow_forwardUse data from problem 32arrow_forwardУл (0.1-b 30 450 2 G 450 1 001 Fig. 2: 2: Strain rosettearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Structural Analysis (10th Edition)Civil EngineeringISBN:9780134610672Author:Russell C. HibbelerPublisher:PEARSONPrinciples of Foundation Engineering (MindTap Cou...Civil EngineeringISBN:9781337705028Author:Braja M. Das, Nagaratnam SivakuganPublisher:Cengage Learning
- Fundamentals of Structural AnalysisCivil EngineeringISBN:9780073398006Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel LanningPublisher:McGraw-Hill EducationTraffic and Highway EngineeringCivil EngineeringISBN:9781305156241Author:Garber, Nicholas J.Publisher:Cengage Learning
Structural Analysis (10th Edition)
Civil Engineering
ISBN:9780134610672
Author:Russell C. Hibbeler
Publisher:PEARSON
Principles of Foundation Engineering (MindTap Cou...
Civil Engineering
ISBN:9781337705028
Author:Braja M. Das, Nagaratnam Sivakugan
Publisher:Cengage Learning
Fundamentals of Structural Analysis
Civil Engineering
ISBN:9780073398006
Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:McGraw-Hill Education
Traffic and Highway Engineering
Civil Engineering
ISBN:9781305156241
Author:Garber, Nicholas J.
Publisher:Cengage Learning