FUNDAMENTALS OF THERMODYNAMICS
10th Edition
ISBN: 9781119634928
Author: Borgnakke
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
Define the no refrigerator can have a higher COP than a reversible refrigerator operating between the same temperature limits.
4. A Camot heat pump with refrigerant-134a as the working fluid is used to keep
a room at 78*F by absorbing heat from geothermal liquid water that enters the
evaporator at 60°C at a rate of 3.78 kg/min and leaves (still as a liquid) at 40°c
The refrigerant, meanwhile, enters the evaporator at 12°C with a quality of 25%
and leaves at the same pressure as saturated vapor. If the compressor
consumes 1.8 kW of power, detemine (a) the mass flow rate (in kg/s) of the
refrigerant at the evaporator, (b) the rate of heat (in kW) supplied to maintain
the room temperature, and (c) the COP. Also, what is (d) the ambient
temperature at the outside, in "C, that necessitates the use of the heat pump?
Assume steam properties to compute for the thermodynamic conditions of
geothermal water.
Outside Inside
Expansion Ve
Condenser
Evaporator
Compresser
A heat engine is operated between temperature limits of 1370 C and 260 C. Engine supplied with 14142 kJ/kW-h. Find the Carnot cycle efficiency.
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- True or false Heat is transferred to a system by either a cheap commercially available air-sourced heat pump with coefficient of performance of just 1.5, or an expensive 100% efficient electrical resistance heater. The loss of Carnot Work Potential (Exergy destruction, or T0Sloss term) is minimum when heat is added by the cheap commercial heat pump. Heat is transferred to a system by either a cheap commercially available air-sourced heat pump with coefficient of performance of just 1.5, or an expensive 100% efficient isothermal heat source. The loss of Carnot Work Potential (Exergy destruction, or T0Sloss term) is minimum when heat is added by the isothermal heat source.arrow_forwardA heat pump receives energy from a source at 80∘C and delivers energy to a boiler that operates at 350 kPa. The boiler input is saturated liquid water and the exit is saturated vapor, both at 350 kPa. The heat pump is driven by a 2.5-MW motor and has a COP that is 60% that of a Carnot heat pump. What is the maximum mass-flow rate of water the system can deliver?arrow_forwardA heat engine operates on a Carnot cycle with an efficiency of 75 percent. What COP would a refrigerator operating on the same cycle have? The low temperature is 0°C.arrow_forward
- I need a step by step solution please :)arrow_forward(c) Consider a house whose annual air-conditioning load is estimated to be 120,000 kWh. The unit cost of electricity is RM0.218/kWh. Two air- conditioners are considered. Air-conditioner Daekon has a seasonal average COP of 3.3 and cost RM3299 to purchase and RM200 to install. Air conditioner Panasini has a seasonal average COP of 5.0 and cost RM6199 to purchase and RM300 to install. Each air-conditioner requires RM50 service fee each year. All else being equal, determine which air-conditioner is a better buy in a long run.arrow_forwardHeat transferarrow_forward
- I need the answer as soon as possiblearrow_forwardTwo engines, one of the auto cycle type and the other of the diesel type, have the same compression ratio and the same amount of heat entering, which one is more efficient? Prove it with a diagram.arrow_forwardDetermine: a)Work of the compressor(kW) b)COP of the cyclearrow_forward
- From the given data, if refrigerant circulation rate is 0.025kg/s, find the refrigerant effect of the ideal vapour compression cycle.arrow_forwardA reversible heat pump is working between 9°C and 28°C. The minimum power required per ton on heating effect is W.arrow_forwardFind the COP of an ammonia refrigeration system that operates between-10℃ to and 32c. at-10℃:hf=154.056 kJ/kg;hg=1448.22 kJ/kg at 32C:hf=351.466 kJ/kg enthalpy after compression is 1670 kJ/kgarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY