Concept explainers
Describe the proper procedure for transporting a total station instrument in the field.
The proper procedure for transporting a total station instrument in the field.
Explanation of Solution
For surveying a given plot the instrument is moved from one station to other station for collection of required data and for accuracy. For any instrument care should be taken while handling it.
Proper handling and care should be taken while moving the instrument as mishandling may cause damage to the instrument and may cause inaccuracy of calculation.
The following steps are to be followed for transporting a total station instrument in the field:
- For moving from one station to other first mark a temporary mark which is used for centering.
- Even for a very small distance a total station should be carried in a locked hard case.
- Do not remove the total station from the hard case till the tripod is fixed firmly on the ground.
- A total station should not be carried on the tripod except for centering.
- A total station should be handled with both hands.
- Total station handle should not be removed till the tripod’s fixing screw is fixed.
- Care should be taken that the tripod is fixed as firmly as possible.
- Always make sure the parts of the total station such as top of the tripod, bottom and top of tribarch and bottom of total station is clean and away from shock.
- Care should be taken while removing a tribarch from the total station.
Want to see more full solutions like this?
Chapter 8 Solutions
ELEMENTARY SURVEYING (LOOSELEAF)
Additional Engineering Textbook Solutions
Elementary Surveying (14th Edition)
Foundation Design: Principles and Practices (3rd Edition)
Structural Analysis (10th Edition)
Materials for Civil and Construction Engineers (4th Edition)
Starting Out with Java: From Control Structures through Data Structures (4th Edition) (What's New in Computer Science)
Java How to Program, Early Objects (11th Edition) (Deitel: How to Program)
- Describe the procedure to adjust an optical plummet on a total station.arrow_forwardWhat is the minimum height of the communication tower in point (B) in order to be observed from point (A) located at The ground level if the distance between the two points is 100 km 100 km- Aarrow_forwardWhat are the functions performed by total station instruments?arrow_forward
- List the types of leveling systems that are used on total station instruments?arrow_forwardCalculate the safe overtuming sight distance for a design speed of 96 kmph. Assume all other data suitably.arrow_forward6.37 (13th) If an EDM instrument has a purported accuracy capability of ±(3 mm = 3 ppm), what error can be expected in a measured distance of (a) 30 m (b) 1586.49 ft (c) 975.468 m? (Assume that the instrument and target miscentering errors are equal to zero.)arrow_forward
- The precision specification for a total station is quoted as ± (2 mm + 2 ppm). Identify and briefly explain the dependent and independent part in the given specification. Calculate the precision in distance measurement for this instrument at 50 m and 2 km?arrow_forwardWhat are the primary sources of random instrumental error in a total station?arrow_forwardKindly answer this, this is in the surveying subject. Thankyou in advance have a nice day! (your explantion) -How to enclose a close traverse? -What is traversing in surveying and what is the importance of this subject in agricultural and biosystem engineeringarrow_forward
- Traffic and Highway EngineeringCivil EngineeringISBN:9781305156241Author:Garber, Nicholas J.Publisher:Cengage Learning