A 50-L electrical radiator containing heating oil is placed in a 50-m³ room. Both the room and the oil in the
radiator are initially at 5°C. The radiator with a rating of 3 kW is now turned on. At the same time, heat
is lost from the room at an average rate of 0.3 kJ/s. After some time, the average temperature is measured
to be 20°C for the air in the room, and 60°C for the oil in the radiator. Taking the density and the specific
heat of the oil to be 950kg/m³ and 2.2kJ/(kg °C), respectively, determine how long the heater is kept on.
Assume the room is well-sealed so that there are no air leaks.
1. An unknown lamp placed 6m from a photometer screen provides the same illuminance as a 90 cd lamp placed 4 m from the screen. What is the candlepower of the unknown lamp?
2. The illuminance of a room 20 ft x 15 ft is being designed. The illuminance required is 50 footcandles. What is the total required lumens output of the lamp assuming room and luminaire efficiency of 42%?
Q. 1/ piece of copper, whose length
is 10 cm and the area of its section
is 6 cm2. Fix one end of it on 150c
and make the other end tangent to
a piece of iron of 8cm length and
equal to it with the cross-sectional
area and straight to one, and the
temperature of the piece of iron
was 20c. Calculate the contact
point temperature between the
two pieces, noting that the thermal
conductivity coefficient of copper
is Scmc / [0.85, while for iron it is
0.75] / ScmC.
Chapter 8 Solutions
MindTap Engineering for Dunlap's Sustainable Energy, SI Edition, 2nd Edition [Instant Access], 1 term (6 months)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- An oil of viscosity 5 poise is used for lubrication between a shaft and sleeve. The diameter of the shaft is 0.5 m and it rotates at 200 r.p.m. Calculate the power lost in oil for a sleeve length of 100 mm. The thickness of oil is 1 mm.arrow_forwardchoose the correct answerarrow_forward12arrow_forward
- choose the correct answerarrow_forwardAn electric baseboard heater has 25 ohms of resistance. The heater uses 9.6amperes of current. Find in volts the voltage required for the heater.arrow_forward4. An incandescent lamp has a tungsten filament whose resistance is 96 ohm at its operating temperature of 2900°C. Calculate the filament resistance when the lamp is disconnected from the electric source under which conditions the temperature is 24°C.arrow_forward
- A forced air system takes return air at 62 degrees Fahrenheit (°F). It heats theair 59°F. What is the temperature of the heated air blown out to the room?arrow_forwardDetermine the luminous efficacy of the following lamps having comparable illumination outputs:a. A 300 W incandescent lamp that emits 5820 lmb. Two 32 W linear fluorescent lamps that emit 2950 lm per lamp in a luminaire that consumes 70 W including the ballastsc. A 70 W metal halide lamp that consumes 88 W, including the ballast and emits 5500 lmarrow_forwardWhen the temperature was 3 deg. C, the distance from E to F was measured using a steel tape that has a standard length of 100m at 20 deg. C with a coefficient of thermal expansion of 0.0000116 / deg. C. If the correct distance from E to F is 836.5 m, what is the measured distance in meters?arrow_forward
- Convert: Convert a (15.5 °C+ 17) temperature into °F temperature.arrow_forwardDesign a temperature indicator system that works in the following manner: 1) D1 will be on when T > 40 C 2) D2 will be on when 40 C > T > 20 C 3) D3 will be on when T < 20 C Use sensor whose resistance varies linearly from 4 kΩ to 12 kΩ as the temperature varies from 10 C to 60 C. Design the needed power supply. Show all your workarrow_forwardCompare the masses and volumes of water, concrete, sand, and wood needed to store 106 Btu of heat if the operating temperatures are Tc = 85F and Th = 180F. In each case, calculate the edge length of a square storage unit with a height of 8 ft.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Engineering Fundamentals: An Introduction to Engi...Civil EngineeringISBN:9781305084766Author:Saeed MoaveniPublisher:Cengage LearningSolid Waste EngineeringCivil EngineeringISBN:9781305635203Author:Worrell, William A.Publisher:Cengage Learning,
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781285852225Author:Gregory W FletcherPublisher:Cengage Learning
Engineering Fundamentals: An Introduction to Engi...
Civil Engineering
ISBN:9781305084766
Author:Saeed Moaveni
Publisher:Cengage Learning
Solid Waste Engineering
Civil Engineering
ISBN:9781305635203
Author:Worrell, William A.
Publisher:Cengage Learning,
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781285852225
Author:Gregory W Fletcher
Publisher:Cengage Learning