Draw the major control devices of a programmable controller.

Answer to Problem 1SQ
The major control devices of a programmable controller are as follows:
Explanation of Solution
Discussion:
A solid-state, electronic microprocessor-based control system is known as a programmable controller.
A programmable controller contains the following components.
- Power supply.
- Input modules.
- Processor.
- Output modules.
- Programmer.
The input devices such as push buttons, limit switches, and condition sensors are connected to input modules. The input module is monitored by the system to detect changes occurred in the input devices. Depending upon the status of input signals, the controller system reacts using user- programmed internal logic. The response obtained by the controller device is used to drive the output loads such as motor starter, control relays, contactors, and alarms.
The major control devices of a programmable controller are shown in Figure 1.
Conclusion:
Thus, major control devices of a programmable controller are shown in Figure 1.
Want to see more full solutions like this?
Chapter 58 Solutions
EBK ELECTRIC MOTOR CONTROL
- Solve this problem and show all of the workarrow_forwardSolve this problem and show all of the workarrow_forwardA 3 km long multimode step index fibre operating at a bandwidth of 4 Mhz has a core refractive index of 1.48 and a refractive index difference of 1 %. Evaluate the rms pulse broadening per kilometer which results from chromatic dispersion.arrow_forward
- Find the Thevenin Equivalent of the circuit below, show all steps;arrow_forwardFind the Thevenin Equivalent Circuit of the following and find the current through R_L, show all steps;arrow_forwardFind the Thevenin Equivalent Circuit of the circuit below and the current through R_L , show all steps;arrow_forward
- Find the Norton Equivalent of the below and the voltage across R_L, show all steps;arrow_forwardUse Mesh Analysis to find the current through the laod resistor R_L. Show all steps;arrow_forwardFind Thevenin Equivalent of the circuit below and the current through the load resistor R_L. Show all steps;arrow_forward
- If = 5000 A actual time IDMT ---R,, Reand R3 The Tsm relays R, and R3 Draw The characteistic relays time margin between Tsm = 0.5 RCT=500/1 CS-125% TSM = 2 TSM = 0.2 and -0.6 R2 CTS = 500/1 Cs=100% Tsm=0.4 R3 CTS = 400/1 Cs=125% TSM = 2arrow_forwardLet X and Y be random variables having joint density function 01.5). (c) p(x) and p(y).arrow_forwardThe joint density function of two continuous random variables X and Y is: p(x, y) = {cxy 0 < x < 4,1 < y < 5 0 otherwise Find (i) the constant c (ii)P(1arrow_forwardarrow_back_iosSEE MORE QUESTIONSarrow_forward_ios
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning

