Concept explainers
Why are NEMA symbols representing such components as push buttons, limit switches, and float switches not used in a programmable controller schematic?
The reason why the NEMA symbols representing the components like push buttons, limit switches and the float switches are not used in the programmable control switches.
Explanation of Solution
The NEMA symbols are the symbols that are used to represent the electrical components.
Since, the PLC recognize only the closed and the open contacts only and it do not recognize that whether the swtich is connected to a component like push button, float swtich or the limit swtich. This is why the NEMA swtich is used in the programming of PLC.
Thus, to give the idea to PLC about the type of components connected, the NEMA symbols are used.
Want to see more full solutions like this?
Chapter 54 Solutions
INDUSTRIAL MOTOR CONTROL
- Please draw a ladder diagram (plc) for this questionarrow_forward1. A mixing vat has an inlet valve, an outlet valve, a mixing motor, and a single level detecting switch (Figure 1). Both valves are opened by solenoids. The level switch closes when the vat is full and stays closed until the vat is empty. Draw a PLC ladder logic diagram and provide the allocation list to do the following: a. When the start button is pushed, the inlet valve opens until the vat is full. b. The mixer motor comes on for 5 min. c. The outlet valve opens until the vat is empty. (closed) Level switch Motor Inlet valve Outlet valve Float Vat Figure 1arrow_forwardList four basic rules for developing a program for a PLC.arrow_forward
- Why are NEMA symbols such as push buttons, float switches, or limit switches not used in programmable logic controller schematics?arrow_forwardWhen programming in Boolean, what statement should be used to connect components in series?arrow_forwardIn what ways do controllers for various devices aid in operation?arrow_forward
- dear eng pls ans quickly thanksarrow_forwardKindly follow the instructions given in the photo. Answer it ASAP because I really need it right now, and make your answer/solution readable. Thanks!arrow_forwardSápport Supp Suppórt Support 5 Types of External Connections (Pin, Ball in Socket (3D pin), Fix, Roller/Rocker, Sliding Support, Bearing) Question: Choose the type of External Connections for each image above and explain why?arrow_forward
- Name Section 5-2: Line Diagrams-Signals, Decisions, and Actions In the following application, a temperature switch controls a heating contactor and a flow switch is used to ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required information. 1. List all the signal devices in the circuit. 2. List all the action devices in the circuit. 3. List the decision part of the circuit that automatically sounds the alarm if there is a problem. 4. When the heating element is on during normal operation, is the flow switch open or closed? CIRCULATING 2 L1 FAN TEMPERATURE SWITCH TR HEATING ELEMENTS FLOW SWITCH -HOT AIR PADDLE AIR FILTER NORMALLY CLOSED FLOW SWITCH 65 ALARM (SOUNDS IF NO FLOW FOR 15 SECONDS OR MORE) Date HEATING CONTACTOR TR ON-DELAY TIMER SUPPLY AIR COLD AIR (3) TIME SET= 15 SEC © 2014 American Technical Publishers, Inc. All rights reservedarrow_forwardCold water enters the heat exchanger system as seen in the figure, and cold water heats up through the Steam entering the heat exchanger. Draw the general control block diagram of this system, name the system components and signals on the diagram.arrow_forwardI need PLC diagram on PLC software or by hand.arrow_forward
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningPrecision Machining Technology (MindTap Course Li...Mechanical EngineeringISBN:9781285444543Author:Peter J. Hoffman, Eric S. Hopewell, Brian JanesPublisher:Cengage Learning