Concept explainers
Explain the necessity of
Explanation of Solution
A motor cannot be completely stopped by applying the dynamic braking alone. In dynamic braking process, the DC motor acts as a generator by reconnecting the running motor, as a result the field gets excited and a low resistance path is created across the armature. Some of the mechanical energy of motor is converted to electrical energy resulting in the reduction of motor speed, current, generator action and the braking lessens. However, the motor does not attain complete stand-alone state due to dynamic braking, the mechanical brake is needed to stop and hold the drive at the final stage of braking.
Conclusion:
Thus, the necessity of the mechanical brake after dynamic braking occurs is explained.
Want to see more full solutions like this?
Chapter 50 Solutions
Electric Motor Control
- What is regenerative braking in electric cars and how does it work?arrow_forward(B)- Indicate whether the following statements are true or false and correct the false statements 1- Wave wound armature has two parallel paths. 2- The current ratio is equal to 1/ turn ratio at no-load while the voltage ratio is equal to 1/ turn ratio at full load 5.4. 3-When a series de motor is operated without a load, the armature draws excessive current Ph 4- The hysteresis loss can be minimized by using core of thin laminations ل لهول 259 Ne 02arrow_forwardOne type of failure that's more common with 200 HP motors than with 10 HP motors is A. rotor bar failure.B. contactor failure.C. bearing failure. D. stator failures.arrow_forward
- 1) Does the motor constant depend on the angular speed? 2) Does motor efficiency, ratio of Vemf to Va, depend on the angular speed of the motor? 3) Does the motor constant depend on the load? 4) When the magnetic load on the motor increases, does the current increase, remain constant, or decrease?arrow_forwardWrite short note on rheostatic braking and plugging brakingarrow_forwardrotor copper loss is ? motor input power is ? motor stating torque is ? motor mechanical torque is ?arrow_forward
- 1- Why D.C motor can be consider a useful for operating equipment such as winches, cranes, and missile launchers? 2- Define the motor. 3- How we can find the direction of mechanical force in motor? 4- What is the magnitude of the mechanical force of the motor? 5- Is there a constructional differences between D.C motor and D.C generator? 6- What is the function of a commutator in the motor ? 7- What will happened if the armature current is turned on when a = 900? 8- Why the counter emf effectively cancels part of the armature voltage? 9- Why counter emf cannot be equal to or greater than the applied battery voltage? 10- What is the benefit of counter emf and what will happened If there were no such thing as counter emf? 11- Shunt motors should never be started on heavy loads, Why? 12- Why in shunt motor with armature current increase speed drops ? 13- Why series motor used with heavy masses? 14- Why series motor should never started without load on it? 15- Why The speed of cumulative…arrow_forwardQ12-Indicate whether the following statements are true or false and correct the false statements. 4- The generation of electricity achieved by moving a conductor in a magnetic field due to the relation E= ILB 5- In series d-c generator the field winding will be constructed from high number of turns and high cross- sectional area of wire. 6- Series motor maintains a more constant speed under varying load 7-The armature voltage of d.c series generator is not affected by load current. 8- In series d-c generator the field winding will be constructed from high number of turns and high cross- sectional area of wire. 9- If field resistance of a d.c. shunt generator is increased beyond its critical value, the generator output voltage will exceed its rated voltage 10-The inter pole winding is connected in parallel to field windingarrow_forwardQuestion 1 [Soalan 1] (a) The model for a position control system using a DC motor is shown in Figure 1.1. Calculate the value of K₁ and K₂ so that the response peak time is 0.2 second and the overshoot for a unit step input is less than 4%. [Satu model untuk satu sistem kawalan kedudukan yang menggunakan motor DC ditunjukkan didalam Rajah 1.1. Kirakan nilai K, dan K₂ supaya sambutan masa puncak ialah 0.2 saat dan terlajak untuk input unit langkah adalah kurang daripada 4%.] R(s) K₁ s(s+1) 1+ K₂s Figure 1.1 [Rajah 1.1] Y(s)arrow_forward
- How would the shaft speed of the motor change if a negative torque is applied while motor is spinning in negative direction? Don't copy pastearrow_forwardCan you please provide a clear and readable solution for this problem about rotational mechanical systems with gears? Super thanks!arrow_forwardAnswer True or False, and correct the false statements for the following 1. Compound-connected D.C. motor is one of the self-excited D.C. motors types 2. Derivative gain in PID controller depends on the accumulation of past errors based onthe rate change of the current 3. Permanent magnetic DC motors are used in hoists and cranes 4. The speed of D.C. shunt motors don't change appreciably when the load torque isincreasing to the rated value 5. The exciting resistance of the transformer is used to generate magnetic flux in thecorearrow_forward
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT