FUNDAMENTALS OF THERMODYNAMICS
10th Edition
ISBN: 9781119634928
Author: Borgnakke
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
A bio-reactor must be kept at 42°C by a heat pump driven by a 3 kW motor. The reactor has a heat loss of 12 kW to the ambient at 15°C. What is the minimum COP that will be acceptable for the heat pump?
A refrigerator in a meat warehouse must keep a low temperature of -20°C and the outside temperature is 25°C. Ammonia is used as the refrigerant which must remove 10 kW from the cold space. Compute for the flow rate of the ammonia needed assuming a standard vapor compression refrigeration cycle with a condenser at 25°C. Find the enthalpy of the stream exiting the evaporator, condenser, and throttling (expansion) valve.
QH -
35 J. What is the
6) The graph in the figure shows a cycle for a heat engine for which
thermal efficiency of this engine?
p (kPa)
400 -
200
V (cm')
200
100
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A gas furnace has an output of 60,000 Btu/h. The return air temperature is 72F, and the temperature out of the furnace is 130F. Disregarding the heat the fan motor may add to the airstream, how much air is the furnace handling?arrow_forwardTwo methods used to power refrigeration compressors on a ship are _____and ____.arrow_forwardA steam plant that could increase the thermal efficiency by using waste heat from the turbune is an example of while that that could use the electical output from the turbine to generate steam to the system is an example of A toy called Drinking bird is an example of (PMM1/PMM2/PMM3/niether of the two) because the power source is (powered by water in the cup/ powered internally my the movement/ none of the option).arrow_forward
- VCRC with Flash Intercooling Use the given-required-solution format and show the unit analysis. Subject: Refrigeration Systems.arrow_forward. A refrigerating system operates on a Vapor compression Refrigeration cycle. The high temperature is at 49C while the low temperature is -12C. The heat absorbed is 70.32 kW. Find the heat rejected and power input.arrow_forwardRefrigeration topic. Please help me answer. Will surely upvote after. Thanksarrow_forward
- Thermodynamics (Carnot Cycle) An Ocean Thermal Energy Conversion (OTEC) power plant produces 25000 kW of ouput using warm surface water temperature of 29°C and a cold deep-water temperature of 12°C. Assume it is a carnot cycle and density of cold water to be 1000 kg/m3. Calculate the heat rejected in kW. Options: a. 920000 b. 720000 c. 120000 d. 420000 e. 820000 f. 320000 g. 520000 h. 220000 i. 620000arrow_forward2.2 A reversed Carnot cycle has a COP for cooling of 4. Determine the tempera- ture ratio TĮT,. If the power consumption of the cycle is 7.5 kW, determine the refrigerating capacity of the machine in TR. If the cycle is used as a heat pump with the same ratio of temperatures, deter- mine its COP for heating and the quantity of heat pumped.arrow_forwardFind the COP of heat pump operating between 1000K and 300Karrow_forward
- A certain power plant produces a net power output of 120 MW. The constant pressure condenser operates at 8 kPa and the constant pressure boiler operates at 1 MPa. The steam enters the turbine, which operates at 88% efficiency at 600°C, and the water leaving the condenser at 8kPa enters the 72% efficient pump. Find: a) mass flow rate in kg/hr of the working fluid, b) heat suplied to the boiler in kJ/hr, c) heat rejected to the condenser in kJ/hr; I want a personalized answer so please do not copy from other's work. I need it ASAParrow_forwardI need answer in handwrittenarrow_forwardA cold storage plant of 30 tonnes of refrigeration capacity runs with its performance just th of its 25% of Carnot COP. Inside temperature is -10°C and atmospheric temperature is 25ºC. Calculate the power required to run the plant. [Note: 1 ton of refrigeration = 3.52 kW]arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Thermodynamic Availability, What is?; Author: MechanicaLEi;https://www.youtube.com/watch?v=-04oxjgS99w;License: Standard Youtube License