Chapter 46, Problem 3RQ
The line that carries refrigerant into the metering device is the
A. suction line.
B. discharge line.
C. liquid line.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1. Describe the operation of a compressor.
Which metering device is most efficient in heat pumps?A. A thermostatic expansion valveB. An automatic expansion valveC. A capillary tubeD. An orifice or restrictor
What kind of circuit balancing valve is used in the hot and chilled water piping?
a. balancing globe valve
b. shut-off balancing valve
c. pressure balancing valve
d. pressure by-pass valve
Chapter 46 Solutions
Refrigeration and Air Conditioning Technology (MindTap Course List)
Ch. 46 - A typical room air-conditioning unit has _____(one...Ch. 46 - Prob. 2RQCh. 46 - The line that carries refrigerant into the...Ch. 46 - Prob. 4RQCh. 46 - Prob. 5RQCh. 46 - Prob. 6RQCh. 46 - Prob. 7RQCh. 46 - Prob. 8RQCh. 46 - Prob. 9RQCh. 46 - Prob. 10RQ
Ch. 46 - Prob. 11RQCh. 46 - Prob. 12RQCh. 46 - Describe the operation of the exhaust and...Ch. 46 - Why should gauges be installed only after there is...Ch. 46 - Prob. 15RQCh. 46 - Prob. 16RQCh. 46 - During the heat pump heating cycle, the hot gas...Ch. 46 - What are two methods used to evaporate condensate...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Which of the following statements is not true about orifice tube systems? The suction line must be cool to the touch from the evaporator outlet to the compressor. The liquid line from the condenser outlet to the evaporator inlet should be cool. The evaporator should feel very cold. The accumulator must be cool to the touch.arrow_forwardFor a hydraulic power unit, this part protects the pump from taking in any harmful particles that may be in the reservoir a. liquid level gauge b. filler/breather c. pressure gauge d. suction strainerarrow_forwardWhen a refrigeration system's suction line is noticeably cold instead of just being cool , it probably contains refrigerant . A. high -pressure liquid B. high -pressure vapor C. low-pressure liquid D. low -pressure vaporarrow_forward
- Which list states the correct order of components for the absorption refrigeration? A) Evaporator, then absorber, then concentrator, then condenser. B) Absorber, then condenser, then evaporator, then concentrator. C) Condenser, then absorber, then concentrator, then evaporator.arrow_forwardGive me correct options with explanation please solve all questions thanksarrow_forwardWhen there is an excess potential energy during the fluid flow, it can be stored using O a. pressure relief valve. O b. pressure reducing valve. O C. accumulator. O d. pressure absorbing valve.arrow_forward
- If a hot water reheat coil is installed with a two way modulating valve. A. The VAV box can only be used for a heating-only application . B. A variable volume circulating pump must be used. C. A constant volume circulating pump can be used. D. The VAV box can only be used for a cooling-only applicationarrow_forwardWhat are the types of Centrifugal Fan?arrow_forwardWhich process would best represent the opposite ofexhausting air from a system?A. CoolingB. VentilatingC. HeatingD. Filteringarrow_forward
- Which of the following is true regarding the refrigerantpiping on a rooftop package unit?A. The discharge and liquid lines must be field installed.B. The suction and liquid lines must be field installed.C. The discharge and suction lines must be field installed.D. No refrigerant lines are field installed.arrow_forwardIn a venturimeter, the velocity of the liquid at the throat is a. higher than inlet b. minimum c. lesser than inlet d. higher than outletarrow_forwardWhat determines the amount of refrigerant that flows through a capillary tube metering device?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningWelding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Quality Control and Quality Assurance; Author: AISC Education;https://www.youtube.com/watch?v=C2PFj9YZ_mw;License: Standard Youtube License