Residential Construction Academy: House Wiring (MindTap Course List)
5th Edition
ISBN: 9781337402415
Author: Gregory W Fletcher
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 4, Problem 13RQ
To determine
The correct word or phrase that best completes the statement.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1. A 150 X 90 X 12 mm angular
section is welded to a gusset
plate shown.
Area of angular section is 2376
sq.mm.
Fu = 550 MPa
Allowable shear Fv=0.30FU
Fy = 250 MPa
Allowable tensile stress Ft =
0.60FY
a. Determine the force P
b. Determine the total length of
weld using 12mm fillet weld
c. Determine the value of a
d. Determine the value of b
wo.t
2-22 mm
(n.)
2-22mm
(d,)
3-22mm
(f)
12m-
23cm
8cm
w 8.1
38 cm.
P.L
40cm
بسته
09-
cm
2.6 m
23-22mm
(2)
-1.22mm (h)
1-22mm)
-1-37m
10mm STPS.
@12mm c/c
-21mx18m
2.1m
L38
cm
25 mm CLEAR.
COVER
3-22 mm (c)
-6-22 mm (d)
-30 cm
-6-22mm (c)
38
cm
SECTION-1-1
10 mm
105
-2-22m.
-2-22 mm STRAIGHT 2
IX
-3-22 mm (f)
PLAN OF 38 cm x 25cm. COLN.
25-22mm (4.h. i)
-10 mm STPS @25cm
-5.5m
BINDER
23 cm
3-22 mm
(c)
1-22 mm.
(8)
10mm
STIRRUPS-
-22 mm
@9 cm c/c (0)
-22 mm @ 9cm c/c (b)
-20 NOS. RODS (LONG SIDE)
17 NOS RODS (SHORT SIDE)
2
-1.37m-
-/4-18mm STR
12 cmc/c
-5-22 mm
(disf)
-4-22mm
(h. i)
125
cm
SECTION 2-2
-50mm CLEAR COVER
-8 cm LEAN CONC. (1:4:8)novations
38
-Prepare a complete schedule of bars of the portal frame as shown in the
4-15. Assume weight of 22mbar-2-98 kg/rm and 10mm bar-0.62 kg/rm.
Twar
469
4 - kindly identify the correct answer, thanks!
Chapter 4 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- Small-appliance branch circuits and laundry branch circuits installed in a dwelling must have a rating of at least__________ amperes. This information is found in NEC Section __________. (Objective 6-2)arrow_forwardCalculate the minimum copper conductor size needed for a 120/240-volt electric range branch circuit. The electric range has a nameplate rating of 12 kW. Show all work. (Objective 6-2)arrow_forwardIn a work situation where an electricians hands get wet while operating a 120-volt, corded drill, which of the following would be true? (Objective 1-1) a. Body resistance increases, and any shock would be mild. b. Body resistance remains the same, and there is no danger as Long as rubber boots are worn. c. Body resistance is substantially decreased, and severe shock could occur. d. There is no danger as Long as a three-prong plug is used.arrow_forward
- A ground resistance meter is used to determine the amount of resistance__________.(Objective 4-7) a. through a grounding electrode to the earth b. though a grounding electrode to the metal frame of an electrical cabinet c. from one end of a grounding conductor to the other end d. from a grounded conductor to the eartharrow_forwardName the ampacity for the following copper conductors according to Table 310.15(B) (16): (Objective 6-4) a. 10 AWG THW amps _____ amps b. 8 AWG THWN amps_______ amps c. 1 AWG THHN amps ______ amps d. 4/0 TW amps ______ ampsarrow_forwardDirections: Circle T to indicate true statements or F to indicate false statements. The higher the resistance in an electrical circuit, the lower the amount of current that can flow in the circuit. (Objective 1-2)arrow_forward
- The most often used category-rated UTP cable for voice and data wiring from various outlets back to the service center or other distribution device in a residential application is______. (Objective 16-3)arrow_forwardWhen wiring a split-wired receptacle, it is recommended that the part of the duplex receptacle controlled by a switch be the _______half and the part that is hot at all times is the ______ half. (Objective 18-3)arrow_forwardThe minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage Learning
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781337402415
Author:Gregory W Fletcher
Publisher:Cengage Learning