Electrical Wiring Residential
18th Edition
ISBN: 9781285170954
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 3, Problem 35R
To determine
Find whether the fixed room dividers and railings shall be considered as the wall space.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
If a recessed luminary without an integral junction boxes installed what extra wiring must be provided
In order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector?
Explain.
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
Chapter 3 Solutions
Electrical Wiring Residential
Ch. 3 - Prob. 1RCh. 3 - How are branch circuits rated? See NEC 210.3._____Ch. 3 - Prob. 3RCh. 3 - Prob. 4RCh. 3 - What spaces are not included in the floor area...Ch. 3 - What is the unit load per square foot for dwelling...Ch. 3 - According to NEC 210.50(C), a laundry equipment...Ch. 3 - How is the total load in volt-amperes for lighting...Ch. 3 - How is the total lighting load in amperes...Ch. 3 - How is the required number of branch circuits...
Ch. 3 - What is the minimum number of 15-ampere lighting...Ch. 3 - How many lighting branch circuits are provided in...Ch. 3 - Prob. 13RCh. 3 - How is the load determined for outlets supplying...Ch. 3 - What type of circuits must be provided for...Ch. 3 - Prob. 16RCh. 3 - In a single-family dwelling, how is overcurrent...Ch. 3 - Prob. 18RCh. 3 - The minimum number of outdoor receptacles for a...Ch. 3 - The Code indicates the rooms in a dwelling that...Ch. 3 - Prob. 21RCh. 3 - Prob. 22RCh. 3 - Prob. 23RCh. 3 - Prob. 24RCh. 3 - Prob. 25RCh. 3 - Although the Code contains many exceptions to the...Ch. 3 - The rating of a branch circuit is based on (Circle...Ch. 3 - a. A 25-ampere branch-circuit conductor is derated...Ch. 3 - Prob. 29RCh. 3 - Prob. 30RCh. 3 - Prob. 31RCh. 3 - Prob. 32RCh. 3 - A split-level home has one stairway that has six...Ch. 3 - Prob. 34RCh. 3 - Prob. 35RCh. 3 - Prob. 36RCh. 3 - In the past, it was common practice to connect the...Ch. 3 - If a residence has two bathrooms, the Code states:...Ch. 3 - Prob. 39RCh. 3 - Prob. 40RCh. 3 - Prob. 41RCh. 3 - Prob. 42RCh. 3 - Prob. 43R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- When calculating a dwelling lighting load on the "volt-ampere per ft" basis, the receptacle load used for floor lamps, table lamps, and so forth arearrow_forwardThe recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardThe coloring on individual conducting wires usually does not indicate a size or rating but rather the standard or preferred use of the wire. For example, black and red wires typically are used for currentcarrying or "hot" connections, and ___ wires usually are grounded "neutral" conductors. Green-insulated wires and bare copper wires are used for grounding wires.arrow_forward
- A device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basinarrow_forwardDetermine the proper size of copper wire conductor necessary to apply a 750 W electric motor that is located 100 feet from the panel board. The voltage at the panelboard is 120 volts. The permissible line drop is 1.2 volts. (for your final answer: no decimal places and unit to have one common answer)arrow_forward2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forward
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardTo answer the question, type your answers in RED or paste the image of your handwriting solution Given the circuit #1 presented above, answer the following questions: Determine the value of the VD (voltage forward of the LED) for the LEDs RED, VDRED, GREEN, VDGREEN and BLUE, VDBLUE, when the current through the LEDs is 10mA, VDRED = ____________ ; VDGREEN = ____________ ; VDBLUE = ____________ Is the LED in Circuit #1, connected in the way that will be lighting up or not – Justify your answer Type your answer here Calculate the value of the resistance Rled in Circuit #1, to ensure that a RED LED will have a current of 10 mA Type your answer here or paste the image of your handwriting solution here Calculate the value of the resistance Rled in Circuit #1, to ensure that a GREEN LED will have a current of 10 mA Type your answer here or paste the image of your handwriting solution here Calculate the value of the resistance Rled in Circuit #1, to ensure that…arrow_forward5. The general receptacle spacing requirements for all dwelling units are located in Section of the NEC. T F 6. The floor receptacle outlets shown in the middle of the workroom are always counted as part of the required number of receptacle outlets as described in Section 210.52(A)(1). 7. The ceiling-mounted decorative light fixture in the covered stoop area weighs 90 lb. Special mounting provisions that apply to this installation are located in Section of the NEC. 8. All exterior luminaires that are exposed to weather shall be markedarrow_forward
- When a three-conductor multi-wire circuit is used in place of two separate branch circuits to supply split-wired receptacles, the grounded (neutral) conductor is required to be ____. A. durably markedB. pigtailed so that its continuity does not depend on the presence of a wiring deviceC. connected to the white or silver-colored receptacle binding screwD. both b and carrow_forwardExplain each option & Choose the correct option. 4) The _ calculated load is rarely placed on an electrical system.A. optionalB. standardC. total 5) What's the primary disadvantage of using copper conductors?A. CostB. AvailabilityC. Weight 6) You're evaluating the components of a multioccupancy building that won't have an on-site employee. To be compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water pump disconnect ..arrow_forwardTOPIC: Power Systems, Power Plants & IlluminationINSTRUCTIONS:- Answer in this format: Given, Illustration, Required Conversion, Solution, Final Answer.- Step-by-step solution, do not skip even simple calculations to avoid confusion.- If answered in written form, make sure it is readable.PROBLEM:In hazardous locations, the use of non-metallic conduit shall be permitted provided it is buried NOT less than ___________ blow the earth level. 400 mm 600 mm 1000 mm 500 mmarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT