ELECTRICAL WIRING:RESIDENT.-TEXT (PB)
19th Edition
ISBN: 9781337116213
Author: MULLIN
Publisher: CENGAGE L
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 28, Problem 3R
a.
To determine
Find the maximum voltage permitted between the conductors when plug fuses are used.
b.
To determine
Check whether Type S plug fuses are permitted to be installed in a switch that disconnects a
c.
To determine
Explain the reason why Type S plug fuses are permitted to be installed in a switch that disconnects a
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
5. An automatic switch or cutout is allowed in the equipment grounding conductor circuit when
A. there's a redundant equipment grounding conductor in the circuit.
B. the power sources are disconnected when operated.
C. it's bonded around the disconnecting device.
D. it also opens the neutral.
12. Which of the following statements about ground faults is true?A. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.B. They usually occur between any grounded circuit conductor and the equipment grounding conductor.C. They can't result from human error.D. They're often normal and typically intentional.
of p
o How many conductors enter the ceiling fan/light wall box?
Switch ond out let boxes
s tirst
10. What type and size of box may be used for the ceiling fan/light wall box?.
11. What type of covers are used with 4 in. square outlet boxes?
12. a. Does the circuit for the Master Bedroom have a grounded circuit conductor?
b. Does it have an equipment grounding conductor?
c. Explain the difference between a "grounded" conductor and an "equipment
grounding" conductor.
13. Approximately how many feet (meters) of 2-wire cable and 3-wire cable are needed to
ft
complete the circuit supplying the Master Bedroom? Two-wire cable:
ft (-
m).
m). Three-wire cable:
14. If the cable is laid in notches in the corner studs, what protection for the cable must be
provided?
15. How high are the receptacles mounted above the finished floor in this bedroom?
16. Approximately how far from the bedroom door is the first receptacle mounted? (See
the plans.)
17. What is the distance from the finished floor to…
Chapter 28 Solutions
ELECTRICAL WIRING:RESIDENT.-TEXT (PB)
Ch. 28 - What is the minimum size service for a one-family...Ch. 28 - Prob. 2RCh. 28 - Prob. 3RCh. 28 - Prob. 4RCh. 28 - Prob. 5RCh. 28 - Prob. 6RCh. 28 - Prob. 7RCh. 28 - List the standard sizes of fuses and circuit...Ch. 28 - Prob. 9RCh. 28 - Using the method shown in this unit, what is the...
Ch. 28 - State four possible combinations of service...Ch. 28 - Which Code section states that all overcurrent...Ch. 28 - All electrical components have some sort of...Ch. 28 - Arc-fault damage is closely related to the value...Ch. 28 - The utility company has provided a letter to the...Ch. 28 - While working on the main panelboard that is...Ch. 28 - Repeat problem 16 for a main service panel that...Ch. 28 - NEC ______________________________ generally...Ch. 28 - Prob. 19RCh. 28 - Prob. 20RCh. 28 - Overcurrent devices must be accessible. (True)...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 8.a. A _______ conductor does not carry current during normal operation.A. neutralB. groundingC. phaseD. grounded8.b. "The complete path of an electric current" describes an electric(al)A. fault.B. circuit.C. source.D. component.arrow_forward1. Alternating current systems of less than _______ volts are required to be grounded if they're installed outside as overhead conductors. A. 50 B. 100 C. 75 D. 120arrow_forward5. How many system bonding jumpers normally are there for a separately derived system that's grounded? A. ThreeB. TwoC. One D. Zero 6. How many grounded neutral conductors are in a 208Y/120 volt, 3-phase, 4-wire system? A. ThreeB. TwoC. One D. Four 7. Which of the following are sometimes installed as an emergency system, legally required standby system, or optional standby power system for a building or structure? A. GeneratorsB. Surge protection devices C. Surge arrestersD. Transformers 8. If the system bonding jumper in a DC system is a screw, what color must the screw be? A. WhiteB. RedC. Orange D. Green 9. If overcurrent protection is provided in the transformer of a separately derived system, which of the following statements is correct? A. An equipment grounding conductor must be run with the conductors between the transformer and the building's disconnect. B. There's no need for service equipment or a panelboard in the separate building.C. A ground electrode must…arrow_forward
- 12. A short circuit describes the condition where there's contact between theA. hot wire and the neutral wire.B. grounded conductor and the grounding wire.C. hot wire and the grounding wire.D. neutral wire and the grounded conductor. I'm not sure if it's the letter A or C, could you help me with the correct answer.arrow_forwardWhich of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardWhich of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forward
- 1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forwardEquipment Grounding 10. Which of the following statements about ground faults is true?A. They usually occur between any grounded circuit conductor and the equipment grounding conductor. B. They're often normal and typically intentional.C. They can't result from human error.D. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.arrow_forward13. Which of the following is a method for identifying a grounding terminal for connecting an equipmentgrounding conductor to a device?A. The letters EGCB. A green octagonal nutC. A red pressure wire connectorD. A green screw with a hexagon headarrow_forward
- 2. When working on a high - voltage system , it is best to keep anyone who is not part of the ser vice away from you and the car by creating a buffer zone around the car . Technician A makes sure the outside edges of the zone are at least one foot away from the car . Technician B places B orange cones to define the outer boundaries of the zone. Who is correct ?arrow_forwardTwo of the circuits will be a 3-wire, multi-wire branch circuit (Edison 3-wire). The location of the devices is to be determined by the student. The student shall be responsible for selecting the correct circuits, do not ask the instructor which circuit number should be used. Circuit A. One lampholder and one duplex receptacle controlled by a Single Pole Switch. Circuit B. Single Pole Switch controlling the top half of a duplex receptacle that when energized, is indicated by a Pilot-light at the Single Pole Switch location; plus an Isolated Ground Duplex Receptacle that is always hot. Circuit C. The bottom half of the switched receptacle on Circuit ‘B’ is to be always hot; plus another Duplex Receptacle that is controlled from two locations using a Coast 3-Way wiring-system.arrow_forwardb) Differentiate between Insulated-Neutral and Earthed-Neutral systems as applied to electrical distribution on board ship. c) Explain with sketches why it is necessary that a single ground fault in an insulated-earth distribution system must be located and cleared immediatelyarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License