Electrical Wiring Residential
Electrical Wiring Residential
19th Edition
ISBN: 9781337101837
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
bartleby

Concept explainers

Question
Book Icon
Chapter 21.2, Problem 1R

a.

To determine

Mention the name of the branch circuit that is connected to the dishwasher.

a.

Expert Solution
Check Mark

Answer to Problem 1R

The dishwasher is connected to circuitB5.

Explanation of Solution

Discussion:

A dishwasher is a machine used for automatic cleaning of dishware and cutlery. It consists of a motor, an electric heating element, and a small fan that is used to circulate hot air during the drying cycle.

A 120 volts, 20 ampere rated dishwasher is connected to B5 branch circuit that originates in Panelboard B.

Conclusion:

Thus, the dishwasher is connected to circuitB5.

b.

To determine

Mention the size of the wire utilized to connect the dishwasher.

b.

Expert Solution
Check Mark

Answer to Problem 1R

The size of the wire utilized to connect the food waste disposer is 12AWG.

Explanation of Solution

Discussion:

A THHN type 12 AWG-sized copper conductors are used to connect the dishwasher to the branch circuit. Any one of the wiring methods among nonmetallic-sheathed cable, EMT, or Type MC cable will be used depending upon the requirement.

Conclusion:

Thus, the size of the wire utilized to connect the dishwasher is 12AWG.

c.

To determine

Explain whether the branch circuit of dishwasher is required to be provided with AFCI protection or not.

c.

Expert Solution
Check Mark

Answer to Problem 1R

Yes, the branch circuit of dishwasher is required to be provided with AFCI protection.

Explanation of Solution

Discussion:

As defined in NEC 210.8(D), AFCI protection is required to be provide for the branch circuit of dishwasher.

Conclusion:

Yes, the branch circuit of dishwasher is required to be provide with AFCI protection.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.
A device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin       c.) Garage basin         d.) Oil catch basin
Which of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT