Referring to the circuit in Figure 2–33, should the float switch be connected as a normally open or normally closed switch?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Should the float switch be connected as a normally open or normally closed switch
Draw a series circuit with a thermostat,a low-pressure switch, and a highpressure switch used as safety controlsto protect a motor
Select the proper choice(s) for each of the following statements:
1) To control single-acting cylinder we just need:
double-acting cylinder we should use
A2/2-way, 5/2-way,
(C) 3/3-way, 3/4-way,
2) In
DCV.
(B) 3/2-way, 4/2-way,
(D) 4/3-way, 3/2-way.
mid poistion of DCV, we can move cylinder piston rod freely without
resistance by hand.
(A) working ports are exhausted,
(C) working ports are pressurized,
3) In pneumatics we use
A Compressor
(B) Pump,
DCV, while to control the
4) Quick exhaust valve is used to
(A) increase the cylinder return speed.
(C) meter-out the cylinder speed
(B) all ports are closed.
no one of these options.
to obtain high pressure air.
(C) Turbine,
(D) pressure relief valve.
(B) meter-in the cylinder speed,
(D) increase the cylinder extending speed.
6) Meter-in of cylinder movement is used to control the
Afluid that enters the hydraulic cylinder,
(B) fluid that exits the hydraulic cylinder,
(C) fluid that enters the DCV
(D) fluid that exits the DCV.
5) One of the…
Chapter 2 Solutions
Understanding Motor Controls
Ch. 2 - Prob. 1RQCh. 2 - The symbol shown is:
Normally closed float...Ch. 2 - The symbol shown is: a. Iron core transformer b....Ch. 2 - The symbol shown is:
Normally open pressure...Ch. 2 - The symbol shown is: a. Double acting push button...Ch. 2 - If you were installing the circuit in Figure 233,...Ch. 2 - Referring to the circuit in Figure 2–33, should...Ch. 2 - Prob. 8RQCh. 2 - Prob. 9RQCh. 2 - When reading a schematic diagram, are the control...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- To answer the following questions refer to the circuit in Figure 416. What is the purpose of the rotary switch connected after the pressure switch?arrow_forwardRefer to Figure 21–1 to answer the following questions. In what position must switch SW 123 be set to make connection between terminals 3 and 4?arrow_forwardTo answer the following questions refer to the circuit in Figure 416. The pressure switch is shown as: a. Normally open b. Normally closed c. Normally open held closed d. Normally closed held openarrow_forward
- When using a rod type float switch, how is the amount float movement required to open or close the contacts adjusted?arrow_forwardRefer to Figure 21–1 to answer the following questions. When switch HOA SW 122 is in the off position, which contacts have connection between them?arrow_forwardRefer to Figure 211 to answer the following questions. Referring to switch (RS SW 123), in what position must the switch be set to make connection between terminals 3 and 4?arrow_forward
- Refer to the circuit shown in Figure 16-11. Assume that the platform is located on the lower floor. When the UP push button is pressed, the platform rises. When the platform reaches the upper floor, however, the pump does not turn off but continues to run until the overload relay opens the overload contacts. Which of the following could cause this problem? a. The solenoid valve opened when limit switch LS1 opened. b. The UP push button is shorted. c. Limit switch LS1 did not open its contacts. d. Limit switch LS2 contacts did not reclose when the platform began to rise.arrow_forwardA pressure switch is to be installed in a circuit that requires it to have three normally open contacts and one normally closed contact. The switch actually has one normally open Contact What must be done to permit this pressure switch to operate in this circuit?arrow_forwardRefer to the schematic in Figure 7-10. Assume that when the START button is pressed, the control transformer fuse blows. What is the most likely cause of this trouble? Figure 7-10 Numbers are placed beside all components.arrow_forward
- An 11-pin control relay contains three sets of single-pole double throw contacts. List the pin numbers by pairs that can be used as normally open contacts.arrow_forwardWhat pin numbers are connected to the coil of an 8-pin control relay?arrow_forwardWhat is the primary use of a limit switch?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781305498129Author:Stephen L. HermanPublisher:Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781305498129
Author:Stephen L. Herman
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Microelectronics Fabrication Center; Author: AnritsuCompany;https://www.youtube.com/watch?v=oDC6WWj3gmk;License: Standard Youtube License