Electrical Wiring: Residental - With Plans (Paperback) Package
18th Edition
ISBN: 9781305416376
Author: MULLIN
Publisher: Cengage
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 19.2, Problem 9R
An 80-gallon electric water heater has 60°F (15.56°C) incoming water. How many minutes can a 3-gallon/minute showerhead be used to draw 105°F (40.56°C) water if the water heater thermostat is set at 120°F (48.89°C)?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.
A
#6 AWG
B
600 Kcmil
C
#8 AWG
D
#2 AWG
What size RMC do we need?
A
3"
B
3/4"
C
1"
D
1 1/2"
We are running 3 wires in an IMC to a control panel with a 150 amp circuit breaker disconnect in the control panel. The conduit is run 12 inches above the roof on a strut rack. The ambient air temperature is 88 degrees. This control panel feeds the #1 cooling fan. What sized ungrounded conductors do we need? All conductors have typeTHHN insulation.
A #1 AWG
B 100 Kcmil
C #1/0 AWG
D #10 AWG
What sized IMC do we need?
A 3/4"
B 1 1/4"
C 1"
D 1 1/2"
Household refrigerators have arrays or coils of tubing on the outside, usually at the back or bottom. When the refrigerator is running, the tubing becomes quite hot. Where does the heat come from?
Chapter 19 Solutions
Electrical Wiring: Residental - With Plans (Paperback) Package
Ch. 19.1 - Does a jet pump have any electrical moving parts...Ch. 19.1 - Prob. 2RCh. 19.1 - Where is the jet of the pump located?...Ch. 19.1 - Prob. 4RCh. 19.1 - Prob. 5RCh. 19.1 - Prob. 6RCh. 19.1 - Prob. 7RCh. 19.1 - What is compressed in the water storage tank?...Ch. 19.1 - Explain the difference between a 2-wire...Ch. 19.1 - Prob. 10R
Ch. 19.1 - Why is a 240-volt motor preferable to a 120-volt...Ch. 19.1 - How many amperes does a 1-horsepower, 240-volt,...Ch. 19.1 - What size are the conductors used for this branch...Ch. 19.1 - Prob. 14RCh. 19.1 - What provides the running overload protection for...Ch. 19.1 - What is the maximum ampere setting permitted for...Ch. 19.1 - Prob. 17RCh. 19.1 - Because the controller contains the motor starting...Ch. 19.1 - Prob. 19RCh. 19.1 - Proper pressure of the submersible pump system is...Ch. 19.1 - Fill in the data for a 16-ampere electric motor,...Ch. 19.1 - The NEC is very specific in its requirement that...Ch. 19.1 - Does the NEC allow submersible pump cable to be...Ch. 19.1 - Must the disconnect switch for a submersible pump...Ch. 19.1 - A metal well casing (shall) (shall not) be bonded...Ch. 19.2 - Prob. 1RCh. 19.2 - A major hazard involved with water heaters is that...Ch. 19.2 - Prob. 3RCh. 19.2 - The heating elements in electric water heaters are...Ch. 19.2 - An 80-gallon electric water heater is energized...Ch. 19.2 - Prob. 6RCh. 19.2 - For residential water heaters, the Consumer...Ch. 19.2 - An 80-gallon electric water heater has 60F...Ch. 19.2 - Approximately how long would it take to produce...Ch. 19.2 - Two thermostats are generally used in an electric...Ch. 19.2 - a. How many heating elements are provided in the...Ch. 19.2 - When does the lower heating element operate?...Ch. 19.2 - Prob. 14RCh. 19.2 - Prob. 15RCh. 19.2 - Prob. 16RCh. 19.2 - a. If both elements of the water heater in this...Ch. 19.2 - a. How much power in watts would the two elements...Ch. 19.2 - A condominium owner complains of not getting...Ch. 19.2 - For a single, nonmotor-operated electrical...Ch. 19.2 - A 7000-watt resistance-type heating appliance is...Ch. 19.2 - Prob. 22R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- According to the following specifications, a single solar 295-watt solar panel has maximum power operation voltage at 24 volts. What is the maximum number of solar panels that can be used in a single string? a. 35 solar panels. b. 30 solar panels. c. 25 solar panels. d. 40 solar panels. e. 20 solar panels.arrow_forward10. Where a single-phase, 240-volt air-conditioning unit has a full-load current rating of 35 amperes, what is the MINIMUM size 75C rated copper conductors required to supply the air- conditioning unit? A. 10 AWG B. 8 AWG C. 6 AWG D. 4 AWGarrow_forwardI need the answer as soon as possiblearrow_forward
- What device is required when the total connected load exceeds the maximum rating of a thermostat? ____________________________________________________________arrow_forwardThyristor switched reactor(TSR) for power factor improvement?(150words)arrow_forwarda. If both elements of the water heater in this residence are energized at the same time, how much current will they draw? (Assume the elements are rated at 240 volts.) b. What size and Type THHN wire is required for the load of both elements? Show calculations.arrow_forward
- 1. Explain why the bedroom light becomes a bit dimmer when an air- conditioning unit is turned on?arrow_forwardWhile discussing evaporative (EVAP) systems: Technician A says that the coolant temperature has to be above a preset value before the PCM will operate the canister purge solenoid. Technician B says that the vehicle speed has to be above a preset value before the PCM will operate the canister purge solenoid. Who is correct?arrow_forwardFor a ceiling heater rated 1440 watts at 120 volts what is current drawarrow_forward
- A computer's power supply converts mains AC to low-voltage regulated DC power for the internal components of a computer. You are building a new computer. You are deciding which type of power supply to install. Which of the following definitions BEST describes a valid type of power supply? Correct Answer: A single-rail power supply provides one rail (PCB trace). This provides the best safety for the computer by providing a single point of shutdown in the event of a short circuit. Correct Answer: A single-rail power supply provides one rail (PCB trace) used to always provide equal wattage to all devices attached to the power supply. Correct Answer: A dual-rail power supply provides separate rails (PCB traces) used to provide equal wattage to the devices attached to each rail. Correct Answer: A dual-rail power supply provides separate rails (PCB traces) used to balance the power load between multiple circuits, which prevents any one circuit from becoming overloaded.arrow_forwardAn uncharged condenser in series with a 120V voltmeter of 10,000 ohms resistance is suddenly connected to a 100V battery. One second later, the voltmeter reads 60 volt. Determine the capacitance of the condenser. *Round off the final answer to the nearest 4 decimal places with unit. Rounding off should only be done on final answer.arrow_forwardTrue or False: A two-stage cooling thermostat would be used on a system with one condensing unit.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License